EWDB 111

APPENDIX 1

Table 10

Complete parameters table

PARAMETER

SEt
diF
HSE
LSE
Ont
OFt
dOn
dOF
dbi
OdO
dit
dtU
dCt
dOH
dEt
dPO
dri
Afd
Att
HAL
LAL
PAO
dAO
tAO
AOP
LOC
PA1
PA2
ndt
CAL
LdL
HdL
dLc
dro
H02
H21
H23 (1)
reL
tAb

LEVEL

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
2
2
2
2
2
2
2
2

RANGE

LSE...HSE
0.3...30.0

LSE..302

-67...HSE

0...250
0...250
0...250
0...250
0...250

0...31

0...250

0/1

0/1/2

0...250
1...250

n/y
n/y

1.0...50.0

0/1

LAL..302

-67...HAL

0...10

0..999

0...250

0/1
n/y

0...255
0...255

n/y

-30...30

-67...302

-67..302

0/1/2

0/1

0…250

0…4
0…4

/
/

DEFAULT

0
2

50

-50

10

0
0
0
0
0
6
0
1
0

30

n

y
2
1

50

-50

2

60

0
1
n
0
0
n
0

-50

110

1
0
5
1
3

/
/

U.M.

°C/°F
°C/°F
°C/°F
°C/°F

min
min

sec

min
min
min

h

num
num

min

min/sec

flag
flag

°C/°F

num

°C/°F
°C/°F

h

min
min

num

flag

num
num

flag

°C/°F
°C/°F
°C/°F

num
num

sec

num
num

/
/

DESCRIPTION

SEtpoint
diFFerential
High SEt
Low SEt
On time compressor
OFF time compressor
dealy On compressor
dealy OFF compressor
delay between interval
Output delay at On
defrost interval time
defrost time unit
defrost count type
defrost Offset
defrost Endurance time
defrost at Power ON
defrost reset interval
Alarm fan differential 
Alarm temperature type
High ALarm
Low ALarm
Power on Alarm Override
defrost Alarm Override
temperature Alarm Override
Alarm Output Polarity
keyboard LOCK
Password 1
Password 2
number display type
CALibration
Low display
High display
display Lock
display read-out
Tempo attivazione tasti
Configurabilità uscita digitale 1
Configurabilità uscita buzzer
reLease Firmware
tAble of parameters

PA2

PA1

folder PL2

St

PL2

PL1

Main Menu

ENTER Key

Tab. 4

folder PL2

folder PL1

folder PL1

Tab. 4

1 2 3

5 6 7 8

1 2 3

5 6 7 8

1 2 3 4 5

7 8

1 2 3 4 5

7 8

WIRING

1 - 2 - 3
4 - 5
5 - 6
7 - 8

compressor relay output
thermostatic sensor input
thermostatic sensor input
power supply

Fig. 2

Menù flowchart

Fig. 3

Schema di morsettiera

Содержание EWDB 111

Страница 1: ...the keys and If the parameter LOC y is not possible to modify the Setpoint MANUAL ACTIVATION OF THE DEFROST CYCLE Manual activation of the defrost cycle is achieved by keeping the key pressed down for Pa H02 seconds KEYPAD LOCK The instrument anticipates by means of appropriately programming the Loc parameter see Table 6 Miscellaneous parameters the possibility of disabling the functioning of the ...

Страница 2: ...rosting 0 interval between two defrost cycles in hours duration of defrost cycle in minutes 1 interval between two defrost cycles in minutes duration of defrost cycle in seconds Defrost interval reckoning mode 0 only the running time of the compressor is counted 1 the running time of the instrument is counted 2 defrosting takes place every time the compressor shuts down Delay in commencement of de...

Страница 3: ... to its automatic operating fea tures as a 1 B type operated control type as a Class A device in relation to the cat egory and structure of the software USE NOT PERMITTED Any other use other than that permitted is de facto prohibited It should be noted that the relay contacts provided are of a practical type and there fore subject to fault Any protection devices required by product standards or di...

Страница 4: ...tial High SEt Low SEt On time compressor OFF time compressor dealy On compressor dealy OFF compressor delay between interval Output delay at On defrost interval time defrost time unit defrost count type defrost Offset defrost Endurance time defrost at Power ON defrost reset interval Alarm fan differential Alarm temperature type High ALarm Low ALarm Power on Alarm Override defrost Alarm Override te...

Отзывы: