background image

 

 

 

 

S

AFETY INFORMATION

 

 

Operate  the  MicroVario  always  in  dry  environment  and  within  the  device  limits  stated  in  this  guide. 
Never expose the device to excessive heat or cold. 

 

Never  apply  mechanical  stress  or  excessive  force  to  the  MicroVario.  The  sensing  element  can  be 
damaged or measure imprecisely if the force is applied. 

 

Do  not  remove  the  heat  shrink  tube  from  the  device  and  do  not  try  to  implement  any  changes  or 
modifications. This can lead to a total destruction and to the denial of any warranty claims. 

 

Always  check  the  polarity  of  the  connection.  Never  inverse  the  polarity  –  this  could  lead  to  total 
destruction. 

W

ARRANTY

 

We  grant  a  warranty  of  24  months  from  the  day  of  purchase  under  the  assumption  that  they  have  been 
operated  in  conformity  with  these  instructions  at  recommended  voltages  and  that  they  were  not  damaged 
mechanically. Warranty and post warranty service is provided by the manufacturer. 

 

Содержание MicroVario

Страница 1: ...te Configuration through the transmitter Firmware updates MICRO VARIO Dimensions 21 5x10x4mm Weight 2g Pressure range 300 1200hPa Altitude resolution 0 1m Typical variometer noise ratio 0 05m s Operating current 15mA Operating temperature 20 85 C Supply Voltage 3 5 12V Telemetry Duplex EX Multiplex MSB Graupner Hott Futaba S Bus2 Status LED YES INSTALLATION Connect the MicroVario directly to the r...

Страница 2: ...soon as the model enters any thermal upstream the vario wil start beeping although the airplane may still be descending o Sealevel Pressure the sea level pressure is taken as a reference to calculate the absolute altitude To get the most accurate calculation of the altitude set the pressure at your location adjusted to the sea level The International Standard Atmosphere Model defines the sea level...

Страница 3: ...plex connection Futaba and Multiplex systems do not offer wireless device configuration The telemetry transmission is possible with the following fixed sensor slots Futaba S Bus2 Multiplex MSB Altitude 19 6 Vario 18 7 Note Manual detection in the menu Linkage Sensor Choose F1672 vario on slot 18 Automatically detected by the transmitter ...

Страница 4: ...ube from the device and do not try to implement any changes or modifications This can lead to a total destruction and to the denial of any warranty claims Always check the polarity of the connection Never inverse the polarity this could lead to total destruction WARRANTY We grant a warranty of 24 months from the day of purchase under the assumption that they have been operated in conformity with t...

Отзывы: