T R O U B L E S H O O T I N G T A B L E
OVERLOAD LED ON
And
POWER LED OFF
1.Short circuit at terminals 8 and 10
2.Short circuit at any of the loop detectors in
the board
3.Short circuit in the control board
1.Remove the short circuit condition at the
terminals
2.Remove the defective loop detector
3.Sent the board to repair
OVERLOAD LED ON
And
POWER LED ON
1. Excessive current draw at terminal 10
2. Over-voltage at the 120 VAC line input
1. Reduce the accessories load from terminal 10
2. Verify your electrical power
SYSTEM ON LED FLASHING
1. One limit switch is faulty
2. Motor thermal fuse has pop-out
1. Test the limit switches and wire connections,
fix the fault
2.Reset the motor
REVERSE SENSOR LED ON
1.Gate has encounter and obstruction during
traveling
2.Reverse sensor is extra sensitive
1.Remove the obstruction
2. Turn counter-clock-wise the reverse sensor
pot a bit more and try again
ALARM SENSOR LED ON
1.Gate encountered and obstruction during
traveling
2.Alarm sensor is extra sensitive
1.Remove the obstruction
2. Turn counter-clock-wise the alarm sensor pot
a bit more and try again
ALARM SENSOR LED ON
1.Gate encountered and obstruction during
traveling
2.Alarm sensor is extra sensitive
1.Remove the obstruction
2. Turn counter-clock-wise the alarm sensor pot
a bit more and try again
COMMAND PROCESSED ON
1. There is a command hold active
1.This is a normal response of the gate
operator. It does not represent necessarily
that there is a problem.
TIMER LED BLINKING And
COMMAND PROCESSED
BLINKING
1. There is a command holding the gate open
1.This is a normal response of the gate operator.
It does not represent necessarily that there is a
problem. Check inputs for command.
TIMER LED BLINKING And
COMMAND PROCESSED
BLINKING
And
REVERSE SENSOR LED ON
1.Gate has reopened because it encountered an
obstruction while closing.
1.Any re-new command will resume normal
operation. Check for obstructions.
2. You can stop the alarm by using the stop
button.
AUDIO ALARM ON
1.Gate has encountered two consecutive
obstructions while trying to close or open
1.Any re-new command will resume normal
operation but not a radio command. Check
for obstructions.
ANY "LOOP LED" ON And
NO VEHICLE ON THE
SENSING AREA
1.The loop detector needs to be reset.
2.The wire loop has been disrupted
3.The loop detector needs to work in a
different frequency
4.The loop detector is too sensitive
1.Reset the loop detector (If you use Elite
Plug-in Loop detectors, change the setting
for sensitivity and come back to your original
setting).
2. Verify and correct connections
3.Set a different working frequency
4.Decrease the sensitivity of the loop detector
C O N D I T I O N
POSSIBLE CAUSES
S O L U T I O N
Содержание CSW-200
Страница 1: ...CSW 200 CSW 200 High Traffic Commercial Swing Gate Operator ...
Страница 18: ...S O L E N O I D M A G L O C K J 3 C O N N E C T I O N Wire Harness ...
Страница 19: ...H O U S E A L A R M P R O X I M I T Y S W I T C H C O N N E C T I O N S ...
Страница 21: ...T E R M I N A L I N P U T C O N N E C T I O N S ...
Страница 28: ...S E C O N D A R Y E N T R A P M E N T M O U N T I N G ...
Страница 31: ...C S W 2 0 0 P A R T S ...
Страница 33: ...A V A I L A B L E P R O D U C T S ...