32
O P T I O N A L D C - 1 0 0 0 U B A C K U P
Bolt-On
Motor
and
Pulley
DC-1000 Unit
Wire
Harness
Option A:
In case of power failure the gate opens
automatically one time and stays open.
When power is restored the operator
returns to normal condition.
Option B:
In case of power failure the gate will not
open automatically until activated by a key
switch or push button. Maintain contact
with the switch or push button until gate is
completely open.
For More Details,
ask your Local Dealer
S T O P B U T T O N A L A R M S H U T - O F F
Omni Option Board Needed
CENTER
SAFETY
EXIT
CENTER
SAFETY
EXIT
FIRE
DEPT.
1
3
STRIKE
OPEN
RADIO
RECEIVER
TIMER
SYSTEM ON
EXIT
LOOP
ALARM
SENSOR
REVERSE
SENSOR
OPEN
ST
OP
CLOSE
SAFETY
LOOP
CENTER
LOOP
GATE
LOCKED
60
POWER
OVERLOAD
OFF
W4
OPEN LEFT
DC-BACKUP
ALARM
SENSOR
OPEN RIGHT
3
SENSORS
RESET
MOTOR
1
3
1
3
COMMAND
PR
OCESSED
ON
G B
MS LINK
A
MADE IN USA
QCC
A
B
OPEN
STOP
CLOSE
MAGLOCK
A L A RM
ARMED
M/ S L INK
OPEN
STOP
CLOSE
1
2
3
4
5
6
Stop
Button
#3 - N.C.
#4 - Com
W4
Cut jumper wire #W4.
Install the stop
button in a secure
accessible place.
This is an important command required to stop the audio alarm in case it has
been triggered. Otherwise the alarm will sound for 5 minutes and reset itself.
• To stop the movement of the gate in case of potential entrapment.
• To reset the audio alarm, (check for obstructions).
• To stop the gate operator while traveling.
Use STOP Button:
When using the Omni option board, use the
“STOP”
input to connect the stop button.