![Elisra MW-IBDB-10W40-PS9 Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/elisra/mw-ibdb-10w40-ps9/mw-ibdb-10w40-ps9_installation-and-operating-instructions-manual_2389387007.webp)
Dekolink Wireless Ltd., 16 Bazel St., Qiryat-Arieh Petah-Tikva Israel, 49510
Tel: 972-3-9180-180; Fax: 972-3-
190
-
9180
Email: [email protected]
:
ENVIRONMENTAL CONDITIONS
Operating temperature
: - 30
°
C to + 50
°
C
Storage temperature
: - 50
°
C to + 90
°
C
:
MECHANICAL SPECIFICATIONS
Size mm(Inch)
265(10.4) x 250(9.8) x140(5.5)
RF Connectors
N-type Female
Weight
8 kg. Approx
RF EXPOSURE WARNING
In order to satisfy the FCC RF exposure requirements, you must ensure that the installation complies
with the following:
One antenna is connected via cable that has typical 1~10 dB attenuation (depends on the length of
the cable) to the BDA base port. This antenna is installed outdoor and has very sharp beam (Yagi
type or similar) pointed to the donor (BTS). This type of antenna has about 10 dBi gain. Typical
specifications: gain: 8 dBd (=10.1 dBi), VSWR: better than 1.5:1 , Impedance: 50 ohm. The outdoor
antenna must be installed to provide a minimum separation distance of 0.5 m (50 cm) from persons
within the area.
The second antenna is connected via cable that has typical 1~10 dB attenuation (depends on the
length of the cable) to the BDA MOBILE port. This type of antenna is omnidirecttional (isotropic), or
wide beam, with 0 to 2 dBi typical gain and is installed and distributes indoor (in buildings, tunnels,
basements, park lots, shopping centers etc.). Typical specifications: gain: 2 dBi, VSWR: better than
2:1 , Impedance: 50 ohm. For direct connection to the BDA this antenna must be installed to provide
a minimum separation distance of 0.
2
m (
2
0 cm) from persons within the area.
;
Web site:
www.dekolink.com