background image

9

Synchronisation Socket (14)
Connect the Sync lead with the traditional EL-synchro socket 14. 

To protect the synchronisation circuits of your camera, Elinchrom uses only 5 Vdc. 

Use only Elinchrom synchro leads, code: 11075.
Charge Socket and Remote control (15)
To charge the Battery, use only the Elinchrom charger Code 19293.

The Ranger RX offers two charging possibilities: Connect the EL charger to the charge socket 15, 

or to recharge the battery externally, release the Battery Box, and connect the charger to the 

charge socket on the Battery Box.

1. Place the Ranger RX pack on a flat and clean surface.

2. Press simultaneously the two push buttons (on each side of the Ranger RX pack).

3. Lift up the Ranger RX pack approx 5 cm and keep pressing the push buttons.

4. The Battery Box slides out by its own weight.

5. Place the new, charged Battery Box on a clean surface.

6. Place the Ranger RX housing over the Battery Box.

7. The Battery Box locates inside the Ranger RX housing.

8. Press down on top of the Ranger RX pack to activate 

    the locking mechanism.

9. Check, that the Battery Box is secure inside the unit!

How to change the Battery Box:

Push button

The charge socket is as well the interface for the EL-Skyport Trigger and Remote System.

With the EL-Skyport RX Trigger Set 19362, the Ranger RX can be triggered wireless, up to 

approximatly 100 m distance. Apart from triggering, the Transmitter offers modelling lamp on/off 

settings and flash power control in 1/10th steps.

By using the EL-Skyport Computer Remote / Trigger Set 19361, 

all Ranger RX functions can be controlled and operated with a Mac° 

or Windows° computer.

Note : 
To connect the Transceiver RX 19353, the  Remote Adapter 19374 is required.

For details of the most advanced wireless system please visit :

www.elinchrom.com/products/RX Multi Remote/EL-Skyport

Wireless Remote Control and Flash Triggering

Содержание Ranger RX

Страница 1: ...English elinca sa switzerland www elinchrom com Operating Manual Elinca S A Ranger RX 01 06 2007 ENG 73300 Printed in Switzerland Battery Power Pack Ranger RX...

Страница 2: ...onformity disposal and recycling CE marking 3 Safety notice and precaution 4 Before you start 5 Control Panel 6 Functions 7 8 Synchronisation Wireless Remote control and flash triggering 9 Change the...

Страница 3: ...equirements of the Canadian Interference Causing Equipement Regulations These limits are designed to provide reasonable protection against harmful interference in a residential installation This equip...

Страница 4: ...thatistheresultofnormaluse Anycomponentsnotreclaimed will be disposed of in a environmentally acceptable manner If you have any question on disposal please contact your local office or your local ELIN...

Страница 5: ...After cooling down the Generator restarts automatically A Beep signal announces that the unit is ready for operation but note that it will only sound if the acoustic signal is switched on The Ranger...

Страница 6: ...mmable explosive material Do not open the unit In the event of damage or apparent failure contact a repair service or any Elinca agent or email elinca elinca ch Always switch off unit before connectin...

Страница 7: ...off with LED indicator Power 7 Power adjustment with ADF Auto Dump Function in 1 10 f stops 8 Power adjustment in 1 10 f stops 9 Digital power display 7 f stops in 1 10 positions Test 10 Open flash 11...

Страница 8: ...reduce the sensitivity of the cell Photocell On Off 4 Slow Charge 3 The green LED indicates that the slow function is selected In slow mode approx 40 more flashes are available About 110 full power fl...

Страница 9: ...reduction but please note that the consequent re charging will reduce the total number of available flashes N B Power indicator 6 flashes during charging and discharging Battery Status Indicator 13 Ap...

Страница 10: ...ged Battery Box on a clean surface 6 Place the Ranger RX housing over the Battery Box 7 The Battery Box locates inside the Ranger RX housing 8 Press down on top of the Ranger RX pack to activate the l...

Страница 11: ...curity cover 16 The 12 V 7Ah Gel Electrolyte Battery can be recharged from any charge level there is no Memory Effect The number of flashes may vary from Battery to Battery due to aging recycling spee...

Страница 12: ...eech lock accepts all Elinchrom Prolinca accessories manufactured since 1974 The Ranger Free Lite S is a universal flashhead for all general studio and location work The Ranger Free Lite A head comes...

Страница 13: ...n be used code 23046 Voltage across sync cable 5 Stabilisation V 1 Battery lead acid V Ah 12V 7Ah Battery recharge time approx h 3 Dimension cm 19 x 14 x 24 22 x 13 5 22 x 13 5 22 x 13 5 Weight kg 6 5...

Страница 14: ...26371 Spots Zoom Spot 18 36 26481 Mini Spot 26420 Stands Stand 85 235cm 30101 Stand Master 109 385 cm 30149B Trigger accessories Universal Set 1x Transmitter 1x Universal Receiver and cables 19360 EL...

Страница 15: ...e and address Ihr voller Name und redet an Votre nom complet et adresse Il suo nome pieno ed indirizza Su nombre y apellidos y dirige In case you cannot register your Elinchrom unit via internet pleas...

Страница 16: ...www elinchrom com...