background image

11

Installation - Ductless (Recirculating) version

CAUTION

To install the hood in this version, first purchase the

Ductless Recirculating Kit.
includes:

charcoal filter and deflector

If possible, disconnect and move freestanding or slide-in
range from cabinet opening to provide easier access to
rear wall. Otherwise put a thick, protective covering over
countertop, cooktop or range to protect from damage
and debris. Select a flat surface for assembling the unit.
Cover that surface with a protective covering and place
all canopy hood parts and hardware in it.

Determine and mark the centerline on the wall where the
canopy hood will be installed.

Select a mounting height comfortable for the user and
mark on wall.

Tape template, matching center-line and hood bottom.

Mounting the duct cover bracket

The duct bracket should be installed against the back wall
and flush with the ceiling.
This bracket will hold the telescopic duct cover in place at
the top.

Secure the bracket to the wall:

Align the marked centerline on the bracket with the
centerline on the wall.
Mark 2 screw hole locations in the wall.
Drill 5/16" pilot holes in the marked locations.
Install wall fastener anchors.
Drive wood screws, by hand, into the fastener to allow
anchors to expand. Remove the screws.
Secure the bracket to the wall with wood screws and/or
fasteners.

House wiring location

The junction box is located on the top left side of the
hood.
Wiring should enter the back wall at least 20 - 1/4"
above the bottom of the installation height, and within 7-
5/8" and 4-7/8"of the left side of the centerline.

Install framing for hood support

If drywall is present, mark the screw hole locations.
Remove the template.
Cut away enough drywall to expose 2 vertical studs at
the holes location indicated by the template.
Install two horizontal supports at least 4" X 2" between
two wall studs at the bottom and upper mounting holes
installation location.
The horizontal support must be flush with the room side
of the studs.
Use cleats behind both sides of the support to secure to
wall studs.
Reinstall drywall and refinish.

IMPORTANT- Framing must be capable of supporting
100 lbs.

Mounting the hood

Install the 8” round transition as shows the image below.
The installation screws and the 8” round transition are
included on the hood package.

8”

Содержание Lugano ELG636SS

Страница 1: ...nstallation Guide Guide d utilisation d entretien et d installation Gu a de instalaci n uso y mantenimiento READ AND SAVE THESE INSTRUCTIONS LISEZ CES INSTRUCTIONS ET CONSERVEZ LES LEA Y GUARDE ESTAS...

Страница 2: ......

Страница 3: ...Shock Do Not Use This Hood With Any External Solid State Speed Control Device WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE a Never leave surface units unattended at high settings Boilovers ca...

Страница 4: ...power supply conduit at the range hood and at the junction box Copies of the standards listed may be obtained from National Fire Protection Association Batterymarch Park Quincy Massachusetts 02269 CSA...

Страница 5: ...ent anchors screws 6 pieces 1 8 x 3 8 Assembly screws 8 pieces Parts not supplied Optional Accessories Ductless Recirculating Kit To be used only in the Ductless Recirculating version includes charcoa...

Страница 6: ...6 Dimensions and Clearances Ductless Recirculating version Only Ducting version Only...

Страница 7: ...und Pipe Preparation Do not cut a joist or stud unless absolutely necessary If a joist or stud must be cut then a supporting frame must be constructed Fittings material is provided to secure the hood...

Страница 8: ...ll Drill 5 16 pilot holes in the marked locations Install wall fastener anchors Drive wood screws by hand into the fastener to allow anchors to expand Remove the screws Secure the bracket to the wall...

Страница 9: ...Mark upper screw holes locations in the wall IMPORTANT Check to be sure that hole locations are leveled and correctly centered by the vertical centerline Drive upper wood screws by hand Leave of dist...

Страница 10: ...Upper Duct Cover may be placed upside down to hide or unhide louver holes Position the duct cover over the mounted hood Slide the bottom of the duct into the canopy area Position the top of the duct...

Страница 11: ...the wall Mark 2 screw hole locations in the wall Drill 5 16 pilot holes in the marked locations Install wall fastener anchors Drive wood screws by hand into the fastener to allow anchors to expand Rem...

Страница 12: ...12...

Страница 13: ...de down to hide or unhide louver holes Position the duct cover over the mounted hood Slide the bottom of the duct into the canopy area Position the top of the duct over the duct mounting bracket If a...

Страница 14: ...14...

Страница 15: ...15...

Страница 16: ...16...

Страница 17: ...ease particles This must be cleaned once a month using non aggressive detergents either by hand or in the dishwasher which must be set to a low temperature and a short cycle When washed in a dishwashe...

Страница 18: ...18...

Страница 19: ......

Отзывы: