14
disposal.
• For further detailed information regarding the process,
collection and recycling of this product, please contact the
appropriate department of your local authorities or the local
department for household waste or the shop where you
purchased this product.
Appliance designed, tested and manufactured according to:
• Safety: EN/IEC 60335-1; EN/IEC 60335-2-31, EN/IEC
62233. • Performance: EN/IEC 61591; ISO 5167-1; ISO
5167-3; ISO 5168; EN/IEC 60704-1; EN/IEC 60704-2-13;
EN/IEC 60704-3; ISO 3741; EN 50564; IEC 62301.
• EMC: EN 55014-1; CISPR 14-1; EN 55014-2; CISPR 14-2;
EN/IEC 61000-3-2; EN/IEC 61000-3-3. Suggestions for a
correct use in order to reduce the environmental impact:
Switch ON the hood at minimum speed when you start
cooking and kept it running for few minutes after cooking is
finished. Increase the speed only in case of large amount of
smoke and vapor and use boost speed(s) only in extreme
situations. Replace the charcoal filter(s) when necessary to
maintain a good odor reduction efficiency. Clean the grease
filter(s) when necessary to maintain a good grease filter
efficiency. Use the maximum diameter of the ducting system
indicated in this manual to optimize efficiency and minimize
noise.
Use
The hood is designed to be used either for exhausting
or filter version
.
Installation
The minimum distance between the supporting surface for the
cooking equipment on the hob and the lowest part of the
range hood must be not less than 60cm from electric cookers
and 65cm from gas or mixed cookers.
If the instructions for installation for the gas hob specify a
greater distance, this must be adhered to.
The mains power supply must correspond to the rating
indicated on the plate situated inside the hood. If provided with
a plug connect the hood to a socket in compliance with current
regulations and positioned in an accessible area, after
installation. If it not fitted with a plug (direct mains connection)
or if the plug is not located in an accessible area, after
installation, apply a double pole switch in accordance with
standards which assures the complete disconnection of the
mains under conditions relating to over-current category III, in
accordance with installation instructions.
WARNING!
Before re-connecting the hood circuit to the mains supply and
checking the efficient function, always check that the mains
cable is correctly assembled.
Operation
The hood is fitted with a control panel with aspiration speed
selection control and a light switch to control cooking area
lights.
Maintenance
Clean using
ONLY
a cloth dampened with neutral liquid
detergent.
DO NOT CLEAN WITH TOOLS OR
INSTRUMENTS
. Do not use abrasive products.
DO NOT USE
ALCOHOL!
Grease filter - Fig. 5-13-14
Traps cooking grease particles.
If situated inside the support grill, it may be one of the
following types:
Paper filter
must be replaced once a month or if colouring
appears on upper side, in such cases the colouring is evident
through the grill openings.
Metallic filter
must be cleaned once a month, with non
abrasive detergents, by hand or in dishwasher on low
temperature and short cycle.
When washed in a dishwasher, the grease filter may discolour
slightly, but this does not affect its filtering capacity.
Charcoal filter (filter version only) - Fig. 13
The saturation of the
charcoal filter
occurs after more or less
prolonged use, depending on the type of cooking and the
regularity of cleaning of the grease filter.
In any case it is necessary to replace the cartridge at least
every four months.
The charcoal filter may NOT be washed or regenerated.
Replacing lamps
Disconnect the appliance from the electricity.
Warning!
Prior to touching the light bulbs ensure they are
cooled down. Replace the damaged lamp.
Use E14 3W max LED lamps only. For more details, check
enclosed leaflet “ILCOS D” (alfanumeric position “
1d
”).
If the lights do not work, make sure that the lamps are fitted
properly into their housings before you call for technical
assistance.
On some models ONLY:
A Non Return Backdraft Damper is included in the supply, as
optional accessory to be installed under certain installation
conditions (i.e. if there is no protection against accidental
backdraft of air from the outside). The damper must be
installed inside the dedicated housing, inside of the Air Outlet
Fitting, before installing the flue.