background image

 
 
 
 
 
 

   Z58-6XX SERIES  

 

 

 

 

 

6 Digits Universal Position Indicator for  

incremental or absolute encoders  

 

 

 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

connectable 

to 

inkremental- 

or 

 

        

absolute encoders (FMAX, FEMAX, EMAX) 

 

approved standard functions 

(e.g. pulse scaling, multi-edge-counter,  

Inch/mm-switch over)   

 

three external inputs (+ 24 V) 

 

serial interface RS-232 

 

analog input 0… 10 V or 0… 20 mA (option) analog output 0... 10 V / 0 

(4)...20 mA (option) 

 

Optionally 2 shutter-relay-outputs (option)

 

 
 

 

Содержание Z58-6 Series

Страница 1: ...inkremental or absolute encoders FMAX FEMAX EMAX approved standard functions e g pulse scaling multi edge counter Inch mm switch over three external inputs 24 V serial interface RS 232 analog input 0...

Страница 2: ...fset 7 6 4 Set to datum value 7 7 TEACHING PROCEDURE 8 8 INFORMATION S ABOUT PULSE SCALING FACTOR 8 9 LIST OF MOST IMPORTANT KEY FUNCTIONS 9 10 SERIAL INTERFACE 10 10 1 Commands 10 11 ERROR NUMBERS 10...

Страница 3: ...ng of actual positions Z58 is a universal device which can work with output signals of all standard linear encoders from ELGO An optional SSI interface allows to evaluate additionally conventional abs...

Страница 4: ...l mode 3 Operation modes Basically two modes are selectable 1 Programming mode setting parameters 2 Normal mode Counting mode Status Relays 2 Option shines if activated Tool Offset shines if activated...

Страница 5: ...ot active 0 1 0 P 05 Front lateral keys 0 active 1 not active 1 1 0000 P 06 Edge multiplier 0 x 1 1 x 2 2 x 4 0 1 2 0 P 07 Selection of measuring system 0 Encoder 1 RS422 Encoder 2 EMAX FEMAX 3 FMAX 0...

Страница 6: ...or the external reference input will be closed P10 Adjustable tool offset This value will be added to the actual value if Button is pressed or the external tool offset input will be closed P11 Saw bl...

Страница 7: ...he display from absolute resp entire to incremental resp relative measurement After switch over to the relative measuring incremental mode the display will be set to zero The further counting proce du...

Страница 8: ...d press Button then The display shows 3 Now move the FMAX sensor to the desired offset and press Button then The display shows 4 With releasing the Button the system is calibrated and the display show...

Страница 9: ...nge reference value P09 Back to normal Operation mode press for 3 sec Tool offset Undo Abs Incr switch over between entire and relative measurement Change to Programming mode for 3 sec at the same tim...

Страница 10: ...h 69h 03h Answer e g 9712 3 decimal bzw 0001 7B63 hexadecimal STX 8 Byte Datas CRC ETX 02h 36h 33h 37h 42h 30h 31h 30h 30h A3h 03h Please note The datas are transmitted in hexadecimal ASCII Code start...

Страница 11: ...bsolute signals relays analog output 1 Screen shield PE 2 GND Encoder supply 3 24VDC 5VDC Encoder supply out 4 RS422_RX 5 RS422_RX 6 RS422_RS485_TX 7 RS422_RS485_TX 8 Analog input 0 10 VDC or 0 20 mA...

Страница 12: ...t 0 10 V G Analog output 0 20 mA H Analog output 4 20 mA Basically the AC variant is offered for replacement of the parent Z54 type Owing to place require ment the functions described above are not re...

Страница 13: ...SSI Interface Standard SSI on request as absolute measuring input Protection class front IP43 installed state Protection class rear IP00 Analog input Option 10 Bit A D Converter 0 10 VDC oder 0 20 mA...

Страница 14: ...14 14 Dimensions 14 1 Measurements of the panel housing in mm Install depth with screw terminals 78 mm Install depth with SUB D connector 115 mm 66 72 91 5 96 64 5 5 5...

Страница 15: ...15 14 2 Measurements of the built on housing Option AG in mm Depth inclusive power plug 160 mm Side view Screw length max 15 mm Side view...

Страница 16: ...z 4 Modulated for connection with ELGO FMAX linear encoder 5 Modulated for connection with ELGO EMAX linear encoder 6 SSI interface on request 7 A B Z 5 VDC Encoder supply 5 V TTL output level PNP 100...

Страница 17: ...ed for any technical modifications without any notice ELGO Electronic GmbH Co KG does not assume any liability for possible errors or mistakes The guarantee period is one calendar year from the date o...