5
4. List of parameters
To lock the programming-level of the menu, please press at the same time,
for 3 seconds…
Æ
Buttons F + Incr/Abs and it appears
Æ
on
Display
Incr/Abs – Button
Æ
Step up the Number of Parameter.
With
▲
- and
►
Buttons it’s possible to select the parameter No. directly:
Button -
►
= select decade Button -
▲
= increase appropriate decade
With F-Button it’s possible to switch-over the sign, with admissible parameters.
Important: Any modification must be stored with the Incr/Abs – Button.
For leaving the setup, press renewed for 3 seconds, at the same time,
the Buttons F + Incr/Abs.
The f
ollowing parameters are available:
No.
Function
Range
DEFAULT
P 00
reserved
P 01
Counting direction (0: up, 1: down)
0, 1
0
P 02
empty
- - - - - -
P 03
Decimal point
0, 1, 2, 3
1
P 04
Power down memory (0: active, 1: not active)
0, 1
0
P 05
Front lateral keys (0: active, 1: not active)
1. 1
0000
P 06
Edge multiplier (0 = x 1, 1 = x 2, 2 = x 4)
0, 1, 2
0
P 07
Selection of measuring-system
(0: Encoder, 1: RS422 Encoder ,
2: EMAX/FEMAX, 3: FMAX,)
0, 1, 2, 3
0
P 08
Pulse scaling factor
0.0001...9.9999 01.0000
P 09
Datum value
-99999... 99999 00000.0
P 10
Tool offset
-99999... 99999 00000.0
P 11
Width of saw-blade
-99999... 99999 00000.0
P 12
Preset relays 1 (min value)
-99999... 99999 00000.0
P 13
Preset relays 2 (max value)
-99999... 99999 00000.0
P 14
Display brightness (0 = dark, 9 = bright)
0...9
5
P 15
Reserved for relay-pulse-time (in preparation)
0
P 16
Set to default parameters (0: no, 1: yes)
0, 1
0
P 17
Measuring unit: mm or inch (0: mm, 1: inch)
0, 1
0
P 18
empty
- - - - - -
P 19
empty
- - - - - -
P 20
Analog-output (min value)
-99999... 99999 00000.0
P 21
Analog-output (max value)
-99999... 99999 00000.0
P 22
empty
- - - - - -
P 23
empty
- - - - - -
P 24
empty
- - - - - -
P 25
empty
- - - - - -
P 26
empty
- - - - - -
P 27
empty
- - - - - -
P 28
empty
- - - - - -
P 29
empty
- - - - - -
P 30… 31 reserved
00000.0
P 32... 98 empty
- - - - - -
P 99
Software version
XX.XX
P
P
0
0
1
1