3. Front view/control elements 

 

 

 

 

 

 

 

 

3.1 Function of the displays 

Actual value

  : 

shows the actual positions of the axes 

Target value

  : 

preset window for the target positions 

Nr.

 

 

 

shows the number of the selected program line 

LED Hand 

 

shines if the button 

„Hand/Single“

 is pressed for 2 times 

LED Single 

shines if the button 

„Hand/Single“

 is pressed for 1 or 2 times 

LED Prog

  

shines if the button 

„Prog“ 

is pressed (program mode active) 

LED P-End

 

shines if the 

end of the program

 is reached 

LED 1 - 3

  

shows which preset window is selected by the

 „>-Button“

 

 

3.2 Function of the keypad 

 
Hand/ Single 

  

1. After pressing the 

Hand/Single

 - Key (LED “Single” shines), the 

X-Axis target  

position

 can be entered. The 

Y-Axis target position

 can be entered with pressing 

 

2. With renewed pressing of 

Hand/Single

 (LED Hand shines additionally) and using  the 

keys 

7, 8, 9, NR,

 the selected axis can be proceeded with 2 speeds in both directions.

 

 

Button 7  

 

=  slow speed backward 

Button 8 

 

=  fast speed backward  

Button 9 

 

=  fast speed forward 

Button Nr.     

=  slow speed forward 

 

The desired axes can be selected by pressing the > - Button. The active axis will be in-

dicated by the LED’s, located below the target windows 
 

Prog  - 

Activates the program line mode 

 

Start - 

Starts the positioning procedure. The 

Start

-Button is disabled in the parameter  

set up mode and during manual inching operation. 

 

Stop - 

Interrupts the positioning procedure. For a new positioning, press 

Start 

again.  

 

 
 

NR.

 

mm

 

Hand

 

Single

 

Prog

 

P-End

 

P8822

 

>

 

>

 

>

ELECTRIC

 

ELGO

 

8

 

9

 

NR

 

5

 

6

 

>

 

2

 

3

 

E

 

7

 

4

 

1

 

C

 

0

 

T

 

R

 

Hand

 

Prog

 

Start

 

Stop

 

Single

 

Содержание P8822-000-P Series

Страница 1: ...P8822 000 P SERIES P8822 000 P V1 8 D_25 04 Dual axes position controller 2 or 3 switched speed operation manual inching mode single set operation 200 line program memory...

Страница 2: ...unction of the displays 6 3 2 Function of the keypad 6 4 CONTROLLER IN OPERATION 8 4 1 Single operation 8 4 2 Program line operation R 8 4 0 8 4 3 Table operation R8 4 1 9 4 4 Manual inching 10 5 REGI...

Страница 3: ...8 FUNCTION OF INPUTS ST3 CONNECTIONS 21 9 FUNCTIONS OF THE OUTPUTS ST4 ST6 CONNECTIONS 23 11 CONNECTIONS 25 12 TECHNICAL SPECIFICATIONS 26 13 INSTALLATION AND WIRING 27 14 ONLY FOR SERVICE 28 15 TYPE...

Страница 4: ...Functions The P8822 controller can be operated with 2 or 3 different speeds 2 1 Two speed operation switched NB R1 R2 R3 The value in Register 1 must be the same value as R2 2 2 Three speed operation...

Страница 5: ...st be present The controller monitors the pulses at intervals set in Register R19 X Y If the Register R19 X Y is set to 0 the monitoring features will be disabled Should a failure occur the ERROR01 is...

Страница 6: ...on can be entered The Y Axis target position can be entered with pressing 2 With renewed pressing of Hand Single LED Hand shines additionally and using the keys 7 8 9 NR the selected axis can be proce...

Страница 7: ...e preset windows sequentially On completion of a line the next press of will select the next address line LEDs 1 3 indicate the selected Window E This button will Set the end of program and reset the...

Страница 8: ...Y will be positioned The next positions can be operated by renewed using of the steps 3 6 then 4 2 Program line operation R 8 4 0 4 2 1 Selection of a program block The P8822 is equipped with a progr...

Страница 9: ...ram is complete now Third step End or continue Press E to end programming Press to continue programming the next line 4 3 Table operation R8 4 1 With setting R8 4 1 R8 XXX1XX the controller operates i...

Страница 10: ...ressed When closed loop analog control is used the respective speeds are set in R60 R63 in rpm The proportional analog output voltage is given when the button is pressed 5 Register Input 5 1 Unlocking...

Страница 11: ...set the old value Type in 200 The window shows 200 i e 20 0 mm Press E The new value is saved now All windows are 0 and the decimal point is reinstated Any Register from 1 to 97 can be selected and ch...

Страница 12: ...itioning 0 2 R 18 5 Keyboard interlock 0 3 R 18 6 Option R 19 Pulse time of encoder monitoring 0 1 sec R 20 Decimal place see page 18 R 28 System Register 3 see page 18 R 29 Time delay for drive inhib...

Страница 13: ...tion will be overrun by the value of R4 and drive back to the target position with creep speed after the time delay of R10 R05 Retract distance X Y There are different modes available in the P8822 sel...

Страница 14: ...speeds independent outputs for speed and direction 5 2 speeds independent speed and direction separate reverse 6 2 speeds separate outputs for each condition 7 2 speeds separate outputs for each condi...

Страница 15: ...X X output activated R8 5 2 2 speeds separate outputs for each condition Output signals ST5 Pin X Y 1 5 2 6 3 7 4 8 Creep forwards X Slow forwards X Fast forwards X Creep reverse X Slow reverse X Fas...

Страница 16: ...ed R8 5 7 2 speeds separate outputs for each condition Output signals ST5 Pin X Y 1 5 2 6 3 7 4 8 Creep forwards X Slow forwards X Fast forwards X Creep reverse X Slow reverse X Fast reverse X X outpu...

Страница 17: ...rect adjustment of R1 R4 other values can be used here R13 R14 Min Max software limits Target Limit R13 error message ERR04 Target Limit R14 error message ERR05 Single operation Immediately after a st...

Страница 18: ...link 0 none R19 cycle time of encoder monitoring If after positioning is initiated no encoder pulses are sensed after a time set in R19 0 1 9 9 s positioning will be aborted and Fault ERROR01 will be...

Страница 19: ...l to R47 the output ready drop of and cycle count is displayed in actual position window The external and front panel Start are disabled To clear the output to allow positioning again R47 must be set...

Страница 20: ...2 Display brightness With the setting of this register the brightness of the display can be altered digitally 0 0 dark 9 9 max brightness R96 Pulse scaling factor A factor 0 00001 9 9999 can be entere...

Страница 21: ...ual value announcements and length parameters are converted in inch ST 3 Pin 6 Keyboard interlock With activating ST3 Pin 6 the keyboard interlock adjusted in R18 5 is unlocked ST 3 Pin 7 Reference Da...

Страница 22: ...ST 3 Pin 18 Retract X Activating of ST3 Pin 18 starts the retract function of the X axis a R 18 X X0XXXX retract distance actual value value in R6 b R 18 X X1XXXX retract to value in R5 c R 18 X X2XXX...

Страница 23: ...n process With pressing START the output positioning in process will be set The output resets first after reaching the target position of both axes and completion of the time in R29 ST 5 Pin 17 progra...

Страница 24: ...24 10 Rear of the unit ST9 ST3 ST5 ST7 Power Supply RS 232 ST1 Encoder Y ST2 Encoder X INPUTS OUTPUTS Fuse 0 4 A 1 2 3...

Страница 25: ...n shield 16 Positioning in process 17 Program end reached Pin ST 9 POWER SUPPLY 230 115 VAC or 24VDC 18 Programm counter reached 1 115 VAC 230 VAC or 24 VDC 19 Positioning X Y completed 2 115 VAC 230...

Страница 26: ...aused short circuit proof with a max load of 50 mA with integrated recovery diode Power down memory E2 Prom service life 105 power on off cycles Connectors D SUB Displays Red LED displays height 10 mm...

Страница 27: ...centrally low ohm to PE earth potential connect only one sided at the P8822 Controller IMPORTANT 1 Don t connect the P8822 s GND to PE earth potential 2 Don t connect the shielding on both sides to P...

Страница 28: ...02 Delete memory 15 Type designation P position controller Series Program memory 1 without 2 with Number of axes Version 000 Standard 001 1 Special version Power supply 024 24 V DC 115 115 V AC 230 23...

Страница 29: ...fore we keep all rights re served for any technical modifications without any notice ELGO Electric does not assume any liability for possible errors or mistakes The guarantee period is one calendar ye...

Отзывы: