INSTR (Instrument) Menu
The
INSTR
menu allows you to:
•
Set the output range (156 or 312 volts).
•
Select either AC or AC+DC coupling.
•
Select current limit mode, either shutdown, foldback or time-out mode
(foldback for the time specified in the ITIMO field then shutdown mode).
Foldback mode is unavailable while SYSTEM/EXTERNAL/ LOW FREQ is on.
•
Select the time for the time-out mode.
•
Select the peak overvoltage limit.
•
Select amplifier parallel operation. When the Parallel mode is ON, only Phase A
will appear in the Program menu. Rear panel output power wiring must match
the Parallel mode selection.
CAUTION!
Parallel mode must match the rear panel
output wiring before programming output amplitude.
PROGRAM
MEASURE
WAVEFORM
SEQUENCE
INSTR
SYSTEM
RANGE
COUPLING
I MODE
I TIMO
V_LIM
PARALLEL
AIN MENU
OUTPUT [OFF]
M
INSTR Menu Status and Information Data:
Menu Item
Status and Information Line Range
RANGE
[156V or 312V range]
156V / 312V
COUPLING
[AC or AC+DC coupling]
AC / AC+DC
I MODE
[supervisory current mode]
Shutdown / Foldback / Time-Out
I TIMO
[current limit time-out]
100–9999 ms
V_LIM
[peak voltage limit]
20–255 Vpk/ 40–510 Vpk
PARALLEL
[parallel output amplifiers]
On / Off
Содержание SmartWave SW1750A
Страница 2: ... ...
Страница 4: ...Committed to Quality Striving for Excellence ii ...
Страница 5: ...This page intentionally left blank iii ...
Страница 8: ......
Страница 31: ...SW 5250A SW 3500A SW 1750A Installation Operation Manual 2 5 Figure 2 3 SmartWave Rear Panel ...
Страница 66: ...Operation SW 5250A SW 3500A SW 1750A 3 22 Operation Manual Table 3 1 Sequence Execute Menu ...
Страница 90: ......
Страница 94: ...Standard Waveforms SW 5250A SW 3500A SW 1750A 4 4 Operation Manual This page intentionally left blank ...