8.  SANITIZATION PROCEDURES 

8.1  Liquid sanitization 

The  normal  sanitization  procedure  for  the 

MEDICA

  unit  is  to  sanitize 

the Reverse Osmosis (RO) module and associated pipework (

8.1.1

). If 

required, the  unit  and  docking  vessel/reservoir  may  also  be  sanitized 
(

8.1.2

). 

8.1.1  RO sanitization procedure 

The  unit  is  sanitized  to  reduce  the  growth  of  microbiological 
contamination  within  the  unit.  The 

MEDICA-R  7/15  US

 

has  a  built-in 

sanitization  port,  which  allows  the  sterilant  to  be  introduced  into  the 
water  feeding  the  RO.  Please  read  this  entire  section  to  become 
familiar with the procedure before you start.  

The  sanitization  frequency  required  is  dependent  on  the  feedwater, 
local environment, usage patterns and  application. As a general rule, 
ELGA  LabWater  recommends  sanitization  of  the  RO  at  6  monthly 
intervals.  However,  the  period  between  sanitizations  could  be 
extended  in  particular  circumstances.  For  example,  microbial  growth 
will  usually  be  lower  with  clean  feed  water,  well-maintained  pre-
treatment, low temperatures and heavy usage. 

 

WARNING!  ALWAYS  WEAR  RUBBER  GLOVES,  APRON  AND 

FACEMASK.  DO  NOT  BREATHE  FUMES  OR  ALLOW 
TO  COME  IN  CONTACT  WITH  SKIN  OR  EYES. 
ALWAYS  FOLLOW  RECOMMENDATIONS  FOUND  IN 
THE  MANUFACTURERS  MATERIAL  SAFETY  DATA 
SHEET  AND  ANY  APPLICABLE  OSHA  STANDARDS 
FOR THE CHEMICAL BEING USED. 

 

WARNING!  LABEL 

THE 

MACHINE 

WITH 

APPROPRIATE 

WARNING  SIGNS  SUCH  A

S  “DO  NOT  USE/ 

CONTAINS STERILANT” (NOT PROVIDED) 

 

 

Minncare Cold Sterilant  is a Peracetic and Hydrogen  Peroxide based 
solution. 

Refer  to  the  Minncare  label  for  additional  information  and  follow  all 
applicable directions for use on the manufacturer’s label in conjunction 
with the following instructions. 

 

Step 1 - Start Sanitization Cycle 

1.  ENSURE that the reservoir level indication on the 

graphics  display  is  showing  >40%.  If  display 
shows  >70%  or  100%,  dispense  water  until 
display changes to >40%. 

2.  PRESS  the  PROCESS  button  to  stop  the 

process. 

3.  TURN OFF the electrical power supply. 

4. 

APPLY  a  suitable  warning  label  such  as  “DO 
NOT USE / CONTAINS STERILANT”. 

5.  RELIEVE  residual  pressure  by  opening  the 

dispense tap and directing water to drain. 

6.  CLOSE the dispense tap. 

7.  DISCONNECT  outlet  tube  at  reservoir  inlet  and  

re-direct  to  a  large  container  (>5litres) 

–  refer  to 

Process flow diagram on p6. 

 

8

0.05

 

Process On 

Содержание MEDICA-R 1-US 5 US

Страница 1: ...MEDICA R 7 15 US Operator Manual...

Страница 2: ......

Страница 3: ...ction and use apply to all media in which this information may be placed VWS UK Ltd pursue a policy of continual product improvement and reserve the right to alter without notice the specification des...

Страница 4: ...MEDICA R 7 15 US Operator Manual ELGA Page ii MEDICA R 7 15 US Version 2 10 15...

Страница 5: ...e MEDICA R 7 15 US 14 5 4 Initial controller set up 17 5 5 Setting up display and replacement timers 18 5 6 Initial start up 21 6 OPERATION 23 7 MAINTENANCE 25 7 1 Replacing the LC140 pre treatment ca...

Страница 6: ...MEDICA R 7 15 US Operator Manual ELGA Page iv MEDICA R 7 15 US Version 2 10 15 13 WARRANTY CONDITIONS OF SALE 47 14 USEFUL CONTACT DETAILS 49...

Страница 7: ...l describe that system Where appropriate reference will be made to differences when an alternative reservoir is used 1 2 Use of this manual This manual contains full details on installation commission...

Страница 8: ...the left hand side of the unit The mains power lead is located just behind the ON OFF switch WARNING THIS APPLIANCE MUST BE EARTHED 2 2 Pressure The main water supply pressure should be isolated and r...

Страница 9: ...urpose disinfecting tablet is used and relevant safety information is included in this handbook Please refer to the manufacturer for material safety data sheets 2 5 Control of Substances Hazardous to...

Страница 10: ...ghly purified water to clinical analyzers requiring a pressurized feed The MEDICA R 7 15 US can be bench or wall mounted with an optional wall mounting kit A range of accessories are available to comp...

Страница 11: ...e sanitization port and through one or two reverse osmosis cartridges set up in series which split the flow into permeate and concentrate streams The permeate water is further purified whilst the wast...

Страница 12: ...id Purified water NRV Temperature sensor Product outlet To analyser Concentrate drain NRV Emergency by pass Flow controller Strainer UV LC105 Line cell Strainer Pump Line cell Permeate Drain Outlet Dr...

Страница 13: ...st pump 6 0 bar 90psi 6 0 bar 90psi Minimum without internal boost pump 4 0 bar 60psi 4 0 bar 60psi Maximum with internal boost pump 2 0 bar 30psi 2 0 bar 30psi Minimum with internal boost pump Floode...

Страница 14: ...d water Temp compensated resistivity conductivity Temperature Degrees centigrade Reservoir Full Pre treatment cartridge Maximum remaining life indicator UV lamp Maximum remaining life indicator Ion ex...

Страница 15: ...er Specification MEDICA R 7 US MEDICA R 15 US Make Up Rate 7 5 l hr 15 l hr Daily Output nominal max 180 l 24 hour day 360 l 24 hour day Purity delivered to analyzer Inorganic Typical 1 to 18 M cm 25...

Страница 16: ...ge 10 MEDICA R 7 15 US Version 2 10 15 MEDICA R 7 15 US Reverse Osmosis Capacity Charts Graph 1 Nominal Flowrate vs Inlet Pressure for MEDICA R 7 US Graph 2 Nominal Flowrate vs Inlet Pressure for MEDI...

Страница 17: ...has a graphics display window and three program function control buttons Details of how to use the controls will be given in the appropriate sections Control Button Function PROCESS Turns the process...

Страница 18: ...a clean dry environment The system can also be wall mounted against a vertical wall capable of supporting the weight for this we recommend the use of the wall mounting kit Part No LA610 CAUTION If th...

Страница 19: ...should have a gravity fall below the level of the unit and any connections direct to drain should have an air break device fitted Feed Water The feed water should be of good quality and comply with sp...

Страница 20: ...reservoir docking vessel Step 1 Fitting Tubes 1 PUSH in collet on connector 2 PULL out transit plug 3 CUT a clean square end on a 8mm 5 16 O D semi rigid drain tube 4 PUSH tube into connector CAUTION...

Страница 21: ...l Supply 1 PLUG mains lead into the socket on the left hand side of the MEDICA unit 2 PLUG mains lead into mains socket Step 3 Connect High Low Level Switch to Reservoir 1 INSERT jack plug into the le...

Страница 22: ...are the recirculation delivery pump connections MEDICA R 7 15 US Unit Installed with Docking Vessel Reservoir Pump and Drain Connections Outlet to Docking Vessel Reservoir Outlet to Analyzer Pump fee...

Страница 23: ...button to go to the next screen to activate the set up menu sequence 3 A series of set up screens will now be displayed Various control icons are used to allow you to step through the set up instruct...

Страница 24: ...with the tick button Note To reset any of the set up parameters restart from the set up menu and follow instructions from Step 1 5 5 Setting up display and replacement timers 1 TURN the unit off at t...

Страница 25: ...re treatment cartridge timer to reset to the preset value of 4380 hours 6 months 1 PRESS tick to jump to the next consumable or to initiate reset 2 PRESS tick to reset timer or press to abort reset 3...

Страница 26: ...emperature Process mimic Reservoir DV level Scroll and Print icons You can scroll through the following display screens RO water conductivity Ion exchange cartridge replacement timer hours remaining U...

Страница 27: ...wn in Section 8 7 ENSURE the cartridge by pass block is left in place until the unit has been rinsed free of bacteriostatic solution 8 TURN ON the electrical supply to the unit and switch the mains sw...

Страница 28: ...ube which supplies the feed to the analyzer PRESS the PROCESS button to start the water purification CHECK unit for leaks 18 Allow the system to operate until the water purity indicator displays a val...

Страница 29: ...lashing icon at the default settings of 8760 hrs 1 year of use PRESS the button to mute the audible alarm FOLLOW the instructions to replace the UV lamp See Section 7 3 Replace pre treatment cartridge...

Страница 30: ...SS the button to mute the alarm If water purity stays outside acceptable purity limits REPLACE the ion exchange pack following the instructions in Section 7 2 Reservoir level disconnect alarm The rese...

Страница 31: ...boost pump when fitted and Recirculation pump from possible debris in the water the unit incorporates two strainers WARNING ALWAYS CHECK THAT THE MAINS ELECTRICAL POWER AND FEED WATER SUPPLIES ARE SWI...

Страница 32: ...m the elbow at the top of the cartridge 5 REMOVE exhausted cartridge from retaining clips and discard Note The consumable is non hazardous Dispose of as ordinary waste observing all local and national...

Страница 33: ...er flow ceases 4 USE an absorbent cloth to soak up the water and RE TIGHTEN the bleed nipple WARNING ENSURE THE UNIT IS ISOLATED BEFORE REMOVING THE ION EXCHANGE CARTRIDGE Step 2 Remove ion exchange c...

Страница 34: ...ed nipple on the 0 2 m capsule filter until water free of air bubbles flows out use an absorbent cloth to prevent splashing of internal components 9 After 20 minutes PRESS the PROCESS button to stop f...

Страница 35: ...he white lamp clip fitted to the bottom of the UV unit CAUTION Hold on to the lamp pins in case the lamp falls out and breaks Step 3 Remove UV Lamp LC105 1 REMOVE old UV lamp from the center bore of t...

Страница 36: ...water and RE TIGHTEN the bleed nipple WARNING ENSURE THE UNIT IS ISOLATED AND THE PRESSURE IS DISSIPATED BEFORE REMOVING THE 0 2 m CAPSULE FILTER Step 2 Remove 0 2 m capsule filter 1 OPEN front door 2...

Страница 37: ...checked and cleaned every six months to ensure that the strainer does not become clogged Step 1 Remove the inlet strainer 1 SWITCH OFF electrical supply 2 OPEN front door 3 ISOLATE inlet water supply...

Страница 38: ...rculation strainer 1 INSERT mesh filter into strainer ENSURE it is facing the correct direction 2 SCREW up the recirculation strainer Step 4 Replace the recirculation strainer 1 REPOSITION the recircu...

Страница 39: ...reatment low temperatures and heavy usage WARNING ALWAYS WEAR RUBBER GLOVES APRON AND FACEMASK DO NOT BREATHE FUMES OR ALLOW TO COME IN CONTACT WITH SKIN OR EYES ALWAYS FOLLOW RECOMMENDATIONS FOUND IN...

Страница 40: ...rises too high in the sanitization port refit the cap and then remove it This will allow room for the remaining 10ml 3 REFIT cap on sanitization port Step 3 By pass Block 1 REMOVE the by pass block fr...

Страница 41: ...the outlet tube to drain 3 RESTORE the power 4 PRESS the PROCESS button and leave the system to rinse for 20 minutes Note during this period the recirculation pump will operate intermittently 5 CHECK...

Страница 42: ...very system docking vessel reservoir The delivery system and docking vessel reservoir may be sanitized to destroy bacteria within the pipework and filters of the unit This sanitization of the system i...

Страница 43: ...CONTACT WITH SKIN OR EYES ALWAYS FOLLOW RECOMMENDATIONS FOUND IN THE MANUFACTURERS MATERIAL SAFETY DATA SHEET AND ANY APPLICABLE OSHA STANDARDS FOR THE CHEMICAL BEING USED WARNING LABEL THE MACHINE W...

Страница 44: ...port Step 3 By pass Block 2 REMOVE the by pass block from its storage position located on the inside of the front door Step 4 Remove Ion exchange Cartridge Pack 3 REMOVE Ion exchange cartridge 4 PLACE...

Страница 45: ...e outlet tube to drain 10 RESTORE the power 11 PRESS the PROCESS button and leave the system to rinse for 20 minutes Note during this period the recirculation pump will operate intermittently 12 CHECK...

Страница 46: ...very system docking vessel reservoir The delivery system and docking vessel reservoir may be sanitized to destroy bacteria within the pipework and filters of the unit This sanitization of the system i...

Страница 47: ...e emergency by pass connector above it 5 RELIEVE any residual pressure in the rest of the system by slowly opening the bleed nipple on the capsule filter until water flow ceases USE an absorbent cloth...

Страница 48: ...nsumption of analyzer 20 l hr Time between pack changes 55 000 605 x 20 Time between Pack changes 4 5 hrs In the absence of information on mains water conductivity assume a pack life of 2 hrs if the a...

Страница 49: ...cartridge replacement alarm Replace pre treatment cartridge see Section 7 1 Replacing the LC140 pre treatment cartridge 0 2 m capsule filter replacement alarm Replace 0 2 m capsule filter see Section...

Страница 50: ...d will depend on the application and feed water quality Care should be taken to order the correct consumable items Required for reservoir DV Required for optional pre treatment filter housing LA518 Ac...

Страница 51: ...ancel Reset Printer 12 2 Alarm Conditions Icon Alarm Conditions Replace Ion exchange pack Replace UV Lamp Replace Pre treatment Cartridge Replace 0 2 micron capsule filter UV Fail Cross Flashes Reserv...

Страница 52: ...US Operator Manual ELGA Page 46 MEDICA R 7 15 US Version 2 10 15 12 4 Low Reservoir Level Poor Water Quality and Standby Screens Screen Description Low level alarm Process on and water purity alarm St...

Страница 53: ...VWS UK Ltd promptly of any such defect The exclusive remedy provided herein shall not be deemed to have failed of its essential purpose so long as VWS UK Ltd is willing and able to repair or replace...

Страница 54: ...customer from the use of its process systems Products or components manufactured by companies other than VWS UK Ltd or its affiliates Non VWS UK Ltd products are covered by the warranty if any extend...

Страница 55: ...Water Lane End Industrial Park High Wycombe Bucks HP14 3BY UK Tel 44 0 203 567 7300 Fax 44 0 203 567 7205 E mail techsupport elgalabwater com For the address of your nearest ELGA LabWater Sales and Se...

Отзывы: