5.3
General settings
5.3.1
Talking settings
Talking time
– determined maximum talking time,
Dialling time
– maximum time for dialling and time for picking up set by fitter,
dialling time =
ringing time + time to pick up
,
Ringing time
– time within which the ring tone is audible,
Picked up ringing time
– time within which a handset connected to the panel rings with special
tone - signalling incorrect receiver putting down,
Redirect unused numbers
– option allows redirecting unused (numbers outside range)
numbers to other selected number, e.g. gatehouse,
Talking time
Talking time can be adjusted within 1 to 255 seconds. Maximum talking time prevents the situation when
too long conversation precludes using the entry phone by other users. To change the maximum talking
time:
§
Enter the menu
Settings
(
code )
§
Select
General settings
(confirm with „
” )
§
Select
Talking settings
(confirm with „
” )
§
Select
Talking time
(confirm with „
” )
§
Screen informing about current setting appears (NOW = X, where X is a number
within 1 to 255 and means the maximum talking time in seconds) to change, press „
”
§
Message appears „SWITCH TO”, in order to enter time in seconds (time
within 1 – 255 seconds) and confirm with key „
” (cancel with „#”).
Default value is 45 seconds.
Dialling time
Dialling time can be set within the range 1-99s. This covers the whole time the panel can use per unit trial of
dialling. It is equal to a ringing time + time of waiting for picking up the receiver by a user. It cannot be
exceeded. In case of selecting longer ringing time - only the waiting time is reduced, but the dialling time
remains as set. To change the time:
§
Enter the menu
Settings
(
code )
§
Select
General settings
(confirm with „
” )
§
Select
Talking settings
(confirm with „
” )
§
Select
Dialling time
(confirm with „
” )
§
Screen informing about current setting appears (NOW= X, where X is a number within 0 to 99 and
means the maximum dialling time in seconds) to change, press „
”
§
Message appears „SWITCH TO”, in order to enter time in seconds (time
within 1 – 99 seconds) and confirm with key „
” (cancel with „#”).
Default value is 45 seconds,
Ringing time
Ringing time can be set by administrator to equal the dialling time at most (note that in such case, picking
up time will be automatically set to 0). If the ringing time has been set to lower value that the dialling time,