Eletrofisher Sum Скачать руководство пользователя страница 2

 

WHAT IS ELECTROFISHING ? 

 

 

Scientists  use  electrofishing  to  survey  fishes  and  monitor 

the  size  of  populations  and  determine  the  species  in  a 
community. Whether using a boat or a backpack electroshocker, 
the  basic  principle  involves  generating  an  electrical  field  in  the 
water to stun fish. When fish are stunned, they often times float 
near  the  surface  of  the  water  and  can  be  removed  from  the 
electrical field. 

How Do Fish Get Stunned? 

 
 

When a fish swims into a weak electrical field, it may not be 

affected at all. There is a threshold of electrical charge that must 
be emitted into the water in order to affect the fish. 
 

When the electrical charge in the water is sufficient to allow 

transport of the charge across the nerve cells in the body, then 
the  fish's  muscles  will  undergo  involuntary  contraction.  The 
contractions will lead to increased exercise of the muscle and a 
build up of lactate in the blood stream. This process is very similar 
to what happens to the muscles of a runner or a swimmer who 
exerts a lot of exercise. The runner or swimmer may eventually 
get a cramp in the muscle and cannot move it effectively. When 
the fish cramps up, it floats to the surface and can be removed 
from the electrical field. The process to stun a fish is usually 5 - 
10 seconds. 
 

Once  the  fish  is  removed  from  the  electric  field,  the  Tidal 

Bass Survey team places the fish in a live well with good aeration. 
The aeration and cool temperatures are essential in the live well 
because the fish has an oxygen debt that needs to be paid. Like 
a  runner  or  swimmer,  the  lactate  in  the  blood  stream  and 
cramping  must  be  treated  with  rest  and  good  oxygen  supply. 
While this period of recovery may take a short time in humans, 

Содержание Sum

Страница 1: ...SUM Electro fisher Manual Poland 2017...

Страница 2: ...ish s muscles will undergo involuntary contraction The contractions will lead to increased exercise of the muscle and a build up of lactate in the blood stream This process is very similar to what hap...

Страница 3: ...teral sensory system and eyesight The black bass may be able to see the boat coming and swim out of the way of the electrical field Many other species of fish such as common carp or longnose gar have...

Страница 4: ...e battery to and When user connects electrofisher in wrong order device will not work User should correctly connect battery to use electrofisher Socket START designed to connect a cable of steering by...

Страница 5: ...t with isolation to landing net in distances 30 50 cm from end so that we could easily operate the landing net and switch on the electrofisher This button is connected with cables of steering output p...

Страница 6: ...the fishing You should hear silent noise and blinking green lamp on the device as well as display showing operating parameters In the course of electrofishing negative electrode is placed in water fr...

Страница 7: ...ce quick and from greater distance On the contrary higher frequency causes smoother exit of fish on the surface Taking into consideration this you should remember increasing of frequency slows down mo...

Страница 8: ...ess the button START for too short time Between maximum and minimum there is an optimum level of power which allows from the point of view of smooth exit of fish to catch them as effectively as possib...

Страница 9: ...cial aims It is advised to boat in the water where the big water holes are present and switching electrofisher for up to 10 minutes observing flowing up catfish in the distance of 15 20 meters After 3...

Страница 10: ...evice Periodically check reliability of contact of cable with anode landing net as well as power supply cables with battery bolts Watch integrity of rubber band on micro switcher of the steering cable...

Страница 11: ...Temperature inside C I Battery current A A Battery voltage V Electro fisher is equipped with three LEDs Battery status Green light Connected battery is charged Red light Connected battery is discharg...

Страница 12: ...uit type 3 anode and cathode too close Error no 7 Anode and cathode short circuit type 4 metallic no 2 Error no 8 Safety problem High Voltage present on electro fisher casing Error no 9 Processor Hung...

Страница 13: ...ly voltage above 5V Error no 30 Probably battery charger is connected It can corrupt electrofisher Error no 31 Safety resistor corrupted Error no 32 Weak battery High start current Error no 33 Safety...

Страница 14: ...ing connecting of battery POWER REGULATION should be set at 100 level Anode examples 1 Oversized Round Anode Ring 2 Diamond Shaped Anode Ring 3 Small Round Anode Ring 4 Round Net Anode Ring 5 Standard...

Страница 15: ...t 128 A peak Output frequency 2 100 Hz in 1 Hz step Overcurrent protection Overvoltage protection Electrofisher automatically is switched off when fall in to a water Catfish option Soft start function...

Страница 16: ...16 ONE TWO THREE YEAR LIMITED WARRANTY Electrofisher Model SUM Name Address Date of Purchase Website www electro fisher net...

Отзывы: