Eletech DM2218C Скачать руководство пользователя страница 8

Application Examples

Automatic Playback on Power-up

1. Repeat continuously on power-up, with no priorities.

Intended Operation

- Play file #001 on power-up if switch #1 is turned on.
- Play file #002 on power-up if switch #2 is turned on.
.........
- Play file #008 on power-up if switch #8 is turned on.
- If more than one switch is turned on, play all corresponding

files sequentially

- Repeat the file(s) until power is turned off.

Required Text in MODE.TXT

RN

Notes

- A direct short can be used if there is only one sound file.
- If priority is required, use DN instead of RN. In this case

switch #1 has the highest priority, switch #2 has the sec-
ond highest priority, and switch #8 has the lowest priority.
If more than one switch is turned on, only the file for the
switch of the highest priority will be played.

2. Repeat at intervals on power-up.

Intended Operation

- Same as the example above but play files at intervals.

Required Text in MODE.TXT

RS
N001=F001,W06000
N002=F002,W06000
.....
N008=F008,W06000
END

Notes

- W06000 is a delay loop of 6000 x 0.1 second = 10 minutes,

so the file(s) will be played at an interval of 10 minutes, one
file at a time.

Application Examples

Using Normally Closed Switches & Sensors

Normally closed switches and sensors are often used in security
systems.

1. Play when the switch/sensor opens, with no priorities.

Intended Operation

- Play file #001 when sensor #1 opens.
- Play file #002 when sensor #2 opens.
- Repeat the sound for as long as the sensor is open.
- If multiple sensors are open at the same time, play all

corresponding files sequentially.

Required Text in MODE.TXT

RN+

Notes

- Unused inputs must be connected to the ground, as shown

in the wiring diagram.

2. Play when the switch/sensor opens, with priorities.

Intended Operation

- Same as the example above, but if multiple sensors are

open at the same time, the sensor of the highest priority
prevails.

Required Text in MODE.TXT

DN+

Notes

- The sensor connected to T1 has the highest priority, and

the sensor connected to T8 has the lowest priority.

3. Play when the switch/sensor opens, but don’t repeat.

Intended Operation

- Play file #001 when sensor #1 opens.
- Play file #002 when sensor #2 opens.
- Do not repeat the sound.

Required Text in MODE.TXT

DS+
N001=F001,J999
N002=F002,J999
H999=J999
END

Notes

- The system will stay in the “H999=J999” endless loop for as

long as the sensor is open. The system will not respond to
other sensors until this one is closed.

DM2218C / EM2218C User’s Manual  -  Page 8 of 8

Содержание DM2218C

Страница 1: ...t to accept a 9 12 VDC supply voltage with jumper J3 at the 12V position If the supply voltage is 6 VDC move jumper J3 to the 6V position Speaker Output Terminals S1 S2 This is a 1 watt bridged balanc...

Страница 2: ...because File 003 is missing The Sequential Trigger is prioritized from T1 the highest to T8 the lowest However it does not mean a higher priority input can interrupt a lower one It only means that if...

Страница 3: ...ng of the script Use this command to turn it on if it has been turned off previously by the BF command END Always add the word END at the end of the entire script You may add any comments for your own...

Страница 4: ...using a Windows utility pro gram called HyperTerminal HyperTerminal allows you to send and receive data through the PC s serial port All you need to do is type the letters on the keyboard to send them...

Страница 5: ...first before starting a new one Stop Playback DTE Sends S System Confirms s If the system is not playing paused it will simply ignore the com mand Otherwise it will terminate the current playback Paus...

Страница 6: ...01tiger wav Note that if you want to store the maximum number of files 512 on a single flash card you should keep the filenames including the file number within 8 characters Any filename longer than 8...

Страница 7: ...ODE TXT DS N001 F001 J888 N002 F002 J888 H888 J888 END Notes The system will stay in the H888 J888 endless loop for as long as the button is held down 4 Play only when the button is held down Intended...

Страница 8: ...Application Examples Using Normally Closed Switches Sensors Normally closed switches and sensors are often used in security systems 1 Play when the switch sensor opens with no priorities Intended Ope...

Отзывы: