14
Magnetic length and angle measuring system
MPI-15
ELESA models all rights reserved in accordance with the law. Always mention the source when reproducing our drawings.
ITA
ENG
FRA
DEU
5. Operating mode
5.1 Commissioning
Use the key to switch on / off the system.
5.2 Absolute mode / incremental mode selection
Press the key to switch from absolute mode to incremental
mode and vice versa. The selected mode is indicated on the display
by the symbols:
ABS
- absolute
◀◀◀
- incremental
When the incremental mode (
◀◀◀
) is selected, the incremental
counter is automatically set to zero.
5.3 Unit of measure selection
If parameter
unitS
is enabled (
EnAbLE
), the unit of measure
is selected by pressing the key. The available options are
the following: mm (0.1), inch (0.001), degrees (0.01), degrees (0.1),
degrees (1).
If parameter
unitS
is disabled (
diSAbLE
), the unit of
measure cannot be changed in the operating mode.
5.4 Direct loading of the absolute reference value
If parameter
LoAdOrG
is enabled (
EnAbLE
) and the absolute
mode is selected (
ABS
), the reference value is directly loaded by
pressing the key.
If parameter
LoAdOrG
is disabled (
diSAbLE
) and the
absolute mode is selected (
ABS
), the reference value is loaded by
pressing the + keys.
The reference value is loaded according to the selected
unit of measure.
5.5 Direct reset of incremental reference value
If parameter
CLr_rEL
is enabled (
EnAbLE
) and the
incremental mode is selected (
◀◀◀
), the display can be set to zero
by pressing the key.
If parameter
CLr_rEL
is disabled (
diSAbLE
), the display
can be set to zero only by switching from absolute mode (
ABS
) to
incremental mode (
◀◀◀
).
5.6 Access the absolute reference value setting
procedure
If parameter
ProGOrG
is enabled (
EnAbLE
) and the absolute
mode is selected (
ABS
), the absolute reference value setting
procedure is directly run by pressing
the + keys.
If parameter
ProGOrG
is disabled (
diSAbLE
), the absolute
reference value setting procedure can be run only accessing the
programming mode.
5.7 Access the offset value setting procedure
If parameter
ProGOFS
is enabled (
EnAbLE
) and the absolute
mode is selected (
ABS
), the offset value setting procedure is
directly run by pressing the + keys.
If parameter
ProGOFS
is disabled (
diSAbLE
), the
offset value setting procedure is directly run only accessing the
programming mode.
5.8 Switching the device ON and OFF
If parameter
on-OFF
is set to
dirECt
, the display is
immediately switch off by pressing the key.
If parameter
on-OFF
is set to
dEL’d
, the display is switch off
by pressing the key for 4 seconds.
4. Keys’ function
Programming
Select value
Select incremental
mode or absolute mode
Select digit
Select unit of measure
Set
function
On / Off
Display:
battery change, unit of measure,
incremental mode, absolute mode,
processing, digits
i