27
EN
DD52R-E-RF
Electronic position indicators
Data transmission via radio frequency
Electronic position indicators
Data transmission via radio frequency
Models all rights reserved in accordance with the law.
Always mention the source when reproducing our drawings.
Parameter
Description
Available options
Standard
value
_ _ _ 0 _ _
Key function
ArCLr
: switching from
ABS
to
REL
the counter is set
to zero.
Ar
: switching from
ABS
to
REL
the counter is not set
to zero.
OFF
: the key is not assigned
to any function in the operating
mode.
ArCLr
_ _ 0 _ _ _
Key function
d_tArG
: during the
positioning press the key
on the display will appear the
target position to reach.
d_toG0
: during the
positioning press the key
on the display will appear the
distance to reach the target
position.
OFF
: the key is not assigned
to any function in the operating
mode.
OFF
0 _ _ _ _ 0
Key
combination
function
+
The key combination activates
the direct programming of the
following parameters:
P_OrG
: parameter
OrG
P_StP
: parameter
StEP
P_OFS
: parameter
OFFS
OFF
: the key combination is not
assigned to any function in the
operating mode.
P_OrG