background image

Installation in round tubes 

 

On the round tube, cut a slot in the end of the tube on the 

drive side. 

 

Push the drive in so that the lug of the drive engages in 

the slot. 

 

Screw in the drive adapter or rivet it. 

 

Establish the electrical connection (see 5.2) 

 

Allow the drive to run in DOWN/CLOSED direction until 

the limit switch cuts out. 

 

Attach the blind to the shaft. 

The drive is fastened on the wall anchor and the blind 

mounted on the shaft using the suitable motor bearings and 

adapter components according to building requirements 

and, depending on the type of blind, with suitable connec-

tion elements, also provided by the system supplier. 
Only operate the drive horizontally as intended. 

5.2  Electrical connection 

WARNING 

Faulty electrical connections constitute a fatal hazard. 
Risk of electric shock. 

 

Prior to initial commissioning, check the PE wire is cor-

rectly connected. 

ATTENTION 

Damage to the VariEco L RH due to incorrect electrical 

connection. 

 

Prior to initial commissioning, check the PE wire is  

correctly connected. 

Damage to or destruction of the VariEco L RH due to 

ingress of moisture. 

 

For devices with protection class IP 44, the customer- 

side connection of the cable ends or plugs (cable feed-

through) can also be implemented according to protection 

class IP 44. 

Damage or destruction of the VariEco L RH for variants 

with 230 V 1 AC due to incorrect activation. 
Switches with an OFF presetting (dead-man's switches) for 

drives are to be attached within visible range of the VariEco 

L RH but away from spontaneously moving parts and at a 

height of more than 1.5 m. 

Important 

There is generally no need to plug the connecting cable 

and plug in and out again for the electrical connection. 

Connect only in de-energised state. To do this, switch 

the drive cable so it is de-energised. 

1  Press locking mechanism on the motor cable plug  

towards the cable using a suitable screwdriver. 

2  

Pull out the plug. 

3  

Insert the motor cable plug until the lock engages. 

4 | EN 

© 

elero

 GmbH 

Product description | Assembly: Mechanical fastening 

Damage to the VariEco L drive due to ingress of moisture.  

 

On devices with protection class IP 44, the ends of all 

cables or plugs will need to be protected from ingress 

of moisture. These measures need to be implemented 

immediately after removing the VariEasy SH drive from 

the original packaging. 

 

The drive must be installed so that it cannot get wet. 

Damage to the blind due to incorrect assembly. 

 

Pay attention to the notes in the manufacturer's  

instructions for blinds and systems. 

Important 

For optimum coordination of drive and blind after assembly 

of the VariEco L RH, adjust the end positions on the drive. 

5.1  Mechanical fastening 

Important preliminary consideration: 

The working area around the installed drive is usually 

very small. For this reason, obtain an overview of how the 

electrical connection has been implemented prior to the 

mechanical installation (see section 5.2) and make the 

necessary changes beforehand. 

ATTENTION 

Crushing or tension will damage the electrical cables. 

 

Install all electrical cabling so that it is not subject to any 

crushing or tensile load 

 

Observe the bending radii of cables (at minimum 50 mm). 

 

Route connecting cables in a downward loop to prevent 

water running into the drive. 

Damage to the drive due to the effect of impact forces. 

 

Slide the drive into the shaft. Never knock the drive in or 

use force! 

 

Take care not to drop the drive! 

Damage or destruction to the drive by drilling. 

 

Never drill the drive! 

Important 

Only secure the VariEco L RH drive using the fastening 

elements provided for this purpose. 
Fixed installed control devices need to be attached so they 

are visible. 
•  The blind must be attached to the winding shaft. 
• 

The profile tube must have sufficient clearance from the 

motor tube. 

• 

Make sure there is sufficient axial play (1 - 2 mm) 

Installation in profile tubes 

 

Push drive with the suitable drive adapter and limit switch 

crown into the profile tube. Install the shaft with drive and 

counterpart support so that the limit switch setting mech-

anism is accessible. 

 

Secure the counterpart support to prevent axial move-

ment (screw on the idler or rivet it on). 

 

Establish the electrical connection (see 5.2) 

 

Allow the drive to run in DOWN/CLOSED direction until 

the limit switch cuts out. 

 

Attach the blind to the shaft. 

Содержание VariEco L RH

Страница 1: ...fety in these operating instructions refers to the laws and regulations that are currently valid in Germany All information in these operating instructions must be complied with at all times and witho...

Страница 2: ...compliance of all safety instructions contained in these operating instructions as well as all valid trade Accident Insurance regulations and valid laws on environ mental protection Use according to i...

Страница 3: ...ion cables motor bearings adapter set if necessary rigid shaft connectors control device If components are not delivered with the drive these can be identified via our catalogue Drives and control uni...

Страница 4: ...riEco L drive due to ingress of moisture On devices with protection class IP 44 the ends of all cables or plugs will need to be protected from ingress of moisture These measures need to be implemented...

Страница 5: ...particularly examined Gratfrei burr free Allgemeintoleranzen General Tolerances DIN ISO 2768 1 m E DIN ISO 2768 2 K E Datum Date Name A EW gepr ft proofed Werkzeug Nr Tool Number G Ge em m R Ro oH HS...

Страница 6: ...ta specified is subject to tolerance factors according to applicable standards and refer to an ambient temperature of 20 C 6 EN elero GmbH Adjustment of the end positions Troubleshooting Take into acc...

Страница 7: ...range revolutions 27 27 27 Operating time min S2 4 4 4 Length C mm 592 592 592 Length D mm 575 575 575 Length E mm 20 20 20 Weight kg 4 7 4 7 4 7 Ambient operating temperature C 20 60 20 60 20 60 Nois...

Страница 8: ...We reserve the right to make technical changes elero GmbH Drive technology Maybachstr 30 73278 Schlierbach Germany info elero de www elero com...