Mounting and initial operation
3
Note:
The maximum limit switch range is 35 revolutions of the
shaft.
Use the adjusting tool for carrying out the adjustment.
Delivery status/factory setting
-
+
-
+
Quick limit switch
adjustment
position „On“
The quick limit switch
adjustment is
activated
at
the factory.
Releasing screw is in the
„On“ position.
The arrow of the releasing
screw points in the direc-
tion of the crown adaptor.
Limit switches are
not
active in the quick limit
switch adjustment.
Adjusting tool
Adjusting tool
13 116.3801
Note:
The limit switches will only work after the motor has been
installed in the shaft.
Quick limit switch adjustment
1. Attach the hangings to the shaft.
Run in the
DOWN
direction if it is necessary to move the
winding shaft.
2. Use the motor cable to move the hangings in the
UP
direction
until you reach the desired limit position.
3. Turn the releasing screw to the „Off“ position.
The arrow of the releasing screw points in the direction of the
cable.
Use an adjusting tool to do so.
4. Both limit positions are now roughly pre-set.
The fine adjustment must be carried out using the individual
adjusting screws.
Only at commissioning
-
+
-
+
Quick limit switch
adjustment
position ”Off“