background image

Adjusting tool for adjusting the end positions 





















































































































































































































































































































































 











 















Article no. 13 116.3801 

ATTENTION 

Use the adjusting tool aid to operate the limit switch  

adjustment screws. 
Only operate the drive horizontally, as intended, with the 

connection cable leading out from the side and out of the 

blind winding area. 

Motor head with adjustments for the limit switch 

³

´

³

´

³

´

5XQGNRSI

6WHUQNRSI

5XQGNRSI

6WHUQNRSI

5XQGNRSI

6WHUQNRSI

5XQGNRSI

6WHUQNRSI

³

´

³

´

³

´

³

´

³

´

 

Fig. 4  Motor head 

5.2  Electrical connection 

WARNING 

Faulty electrical connections constitute a fatal hazard. 
Risk of electric shock. 

 

Prior to initial commissioning, check the PE wire is  

correctly connected. 

ATTENTION 

Damage to the VariEasy SH drive due to incorrect electrical 

connection. 

 

Prior to initial commissioning, check the PE wire is  

correctly connected. 

Damage to or destruction of the VariEasy SH drive due to 

ingress of moisture. 

 

For devices with protection class IP 44, the  

customer-side connection of the cable ends or plugs 

(cable feed-through) can also be implemented  

according to protection class IP 44. 

Damage or destruction of the VariEasy SH drive for variants 

with 230 V / 50 Hz due to incorrect activation. 
Switches with an OFF presetting (dead-man's switches) 

for drives are to be attached within visible range of the 

VariEasy SH drive but away from spontaneously moving 

parts and at a height of more than 1.5 m. 

Important 

There is generally no need to plug the connecting cable 

and plug in and out again for the electrical connection. 

Connect only in de-energized state. To do this, switch 

the drive cable so it is de-energized. 

1  Press the locking mechanism on the MiniPlug connector 

towards the cable using a screwdriver. 

2  Unplug the cable and the 

MiniPlug connector. 

3  Insert the MiniPlug connector

 until the lock engages. 

4 | EN 

© 

elero

 GmbH 

Product description | Assembly: mechanical fastening | Electrical connection 

5.1  Mechanical fastening 

Important preliminary consideration: 

The working area around the installed drive is usually 

very small. For this reason, obtain an overview of how the 

electrical connection has been implemented prior to the 

mechanical installation (see section 5.2) and make the 

necessary changes beforehand. 

ATTENTION 

Crushing or tension will damage the electrical cables. 

 

Install all electrical cabling so that it is not subject to any 

crushing or tensile load 

 

Observe the bending radii of cables (at minimum 50 mm). 

 

Route connecting cables in a downward loop to prevent 

water running into the drive. 

Damage to the drive due to the effect of impact forces. 

 

Slide the drive into the shaft. Never knock the drive in or 

use force! 

 

Take care not to drop the drive! 

Damage or destruction to the drive by drilling. 

 

Never drill the drive! 

Important 

Only secure the VariEasy SH drive using the fastening 

elements provided for this purpose. 
Fixed installed control devices need to be attached so they 

are visible. 
•  The blind/shutter must be attached to the winding shaft. 
• 

The profile tube must have sufficient clearance from the 

motor tube. 

• 

Make sure there is sufficient axial play (1 - 2 mm) 

Installation in profile tubes 

 

Push drive with the suitable drive adapter and limit switch 

crown into the profile tube. Install the shaft with drive and 

counterpart support so that the full adjustment range of 

the limit switch mechanism is accessible. 

 

Secure the counterpart support to prevent axial  

movement (screw on the idler or rivet it on). 

 

Establish the electrical connection (see 5.2) 

 

Allow the drive to run in DOWN/CLOSED direction until 

the limit switch cuts out. 

 

Attach the blind to the shaft. 

Installation in round tubes 

 

On the round tube, cut a slot in the end of the tube on  

the drive side. 

 

Push the drive in so that the lug of the drive engages  

in the slot. 

 

Screw in the drive adapter or rivet it. 

 

Establish the electrical connection (see 5.2) 

 

Allow the drive to run in DOWN/CLOSED direction until 

the limit switch cuts out. 

 

Attach the blind to the shaft. 

The drive is fastened on the wall anchor and the blind 

mounted on the shaft using the suitable motor bearings and 

adapter components according to building requirements 

and, depending on the type of blind, with suitable connec-

tion elements, also provided by the system supplier. 

Star head

Содержание VariEasy M10 SH

Страница 1: ...l information in these operating and assembly instructions must be complied with at all times and without limitation In addition to the safety notes in these instruc tions the regulations on accident...

Страница 2: ...ctions 2 3 Foreseeable misuse Any use that deviates from the intended use as stated by the manufacturer is deemed as foreseeable misuse 2 4 Warranty and liability The General Terms and Conditions of t...

Страница 3: ...shutter The coupling of the drive with the powered part is described in the section Mechanical fastening CAUTION Risk of injuries due to hot surfaces The drive will heat up during operation the drive...

Страница 4: ...erview of how the electrical connection has been implemented prior to the mechanical installation see section 5 2 and make the necessary changes beforehand ATTENTION Crushing or tension will damage th...

Страница 5: ...hold down the UP button and hold it down If the drive switches off before it reaches the desired end position turn the corresponding interior limit switch adjustment for the upper end position see Ch...

Страница 6: ...electrical installation Removal for scrap The international national and regional laws and regulations prevailing at the time of scrapping the product must be observed Ensure that materials and compo...

Страница 7: ...national regulations 11 EU Declaration of Conformity elero hereby declares that this device is in compliance with all applicable regulations of the Machinery Directive 2006 42 EC The full text of the...

Страница 8: ...Rated torque Nm 10 20 30 Rated speed rpm 14 14 14 Rated current A 0 55 0 75 1 10 Rated power consumption W 120 170 250 Shaft diameter 50 50 50 Protection class IP 44 44 44 Limit switch range revolutio...