background image

 

‰

Prior to inspection, assembly and disassembly work, 

the system (awning, roller blind) must be switched to a 

de-energised state. 

 

‰

All electrical connections, safety devices, fuses, etc. must 

be properly installed, connected and earthed. 

 

‰

The power supply provided must be in accordance with 

the electric circuit diagram (voltage type, voltage level). 

 

‰

A miniature circuit breaker (MCB) is sufficient to isolate 

the system from the power supply (if only one phase and 

neutral is used). 

 

‰

If a stationary (permanently installed) drive is not 

equipped with a power cable with a plug or another 

means of disconnecting it from the mains that has a 

contact opening width at each pole according to the 

conditions of overvoltage category III (pursuant to  

IEC 60664-1) for full disconnection, such a disconnection 

device, must be built into the fixed electrical installation in 

accordance with facility requirements. 

 

‰

The mains connection cable for drives with a rub-

ber-sheathed cable (abbreviation 60245 IEC 53) can only 

be replaced with the same cable type. 

 

‰

The following applies to drives that allow physical access 

to unprotected moving parts after installation: Moving 

parts of the drive must be fitted more than 2.5 m over the 

ground (or another level that offers access to the drive). 

Product description 

The SunTop is an electromechanical tubular motor drive for 

window awnings and fabric-based sun protection. During 

operation it executes radial movements. 

 

‰

Commissioning the SunTop with 

elero

 assembly cable for 

adjusting the end positions and relief 

 

‰

Blocking recognition (torque limiting) 

 

‰

Parallel switching 

•  The values for your SunTop that are dependent on the 

version can be found on the type plate. 

• 

The different versions of the SunTop are fitted with dif

-

ferent types of braking systems, depending on the rated 

torque and size. This, in turn, can lead to different oper

-

ating behaviour, e.g. with respect to approaching an end 

position. 

4.1  Product contents 

Drive with safety instructions and operating instructions and 

any additional components and accessories according to 

the order confirmation or delivery note. 

4.2  Accessories 

Connection and assembly cables, adapter sets, motor bear-

ings, ProLine control units, sensors, radio receivers, bearing 

plates, shaft bearings. 

Assembly 

WARNING 

Risk of injury due to incorrect assembly 
Important safety instructions 

 

Observe all assembly instructions. Incorrect assembly 

can lead to serious injuries. 

CAUTION 

Risk of injuries due to hot surfaces. 

4 | EN 

© 

elero

 GmbH 

Product description 

 

‰

If any risk to persons or operational changes are detect-

ed, the product must be taken out of operation immedi-

ately and the plant operator informed accordingly. 

 

‰

No changes, conversions or attachments may be made 

to the product without the permission of the manufacturer. 

 

‰

The system must be frequently checked for improper 

balance, signs of wear, and damaged cables and springs 

(if applicable). 

3.7  Safety notices and directions relating to 

transport, assembly and installation 

The respective shipping company is responsible for ship-

ping the product. The following safety requirements must 

be observed when transporting, assembling and installing 

the product: 

 

‰

The product must be secured in line with the require-

ments defined for the transport aid during shipment. 

 

‰

Only lifting gear and lifting tackle that can comfortably re-

sist the forces encountered during loading, unloading and 

assembling the product may be used during transport. 

 

‰

Only the designated areas indicated on the pallet and the 

product may be used as attachment and lifting points. 

 

‰

During assembly work above head height, use suitable, 

inspected and structurally stable climbing aids. 

 

‰

If work must be performed on raised parts or working 

equipment, these parts or equipment must be secured 

against falling down using suitable devices. Tools used to 

lift loads must prevent the loads from unintentionally shift-

ing, freely falling or inadvertently becoming unhooked. 

 

‰

Standing under suspended loads is prohibited. 

 

‰

A safety helmet must be worn during loading work with 

lifting gear. 

 

‰

Assembly and installation work may only be performed by 

trained and instructed specialist personnel. 

 

‰

The rated torque and rating operating time must be suit-

able for the properties of the driven part (the blind). 

 

‰

On the SunTop type M, the smallest internal tube diame-

ter of the winding shaft is 47 mm; on the SunTop type L, 

it is 58 mm. 

3.8  Safety instructions relating to operation 

 

‰

The plant operator responsible for the product is obligat-

ed to ensure that it is in safe and proper condition prior to 

initial commissioning. 

 

‰

Such checks must also be conducted during operation of 

the product at regular intervals determined by the plant 

operator. 

 

‰

The SunTop produces mechanical noise when it is op-

erated. The A-rated emission sound pressure level does 

not exceed 70 dB(A). 

3.9  Safety notices and directions relating to the 

electrical installation 

 

‰

All work on the electrical equipment of the system may 

only be carried out by authorised electricians according 

to the applicable rules and regulations of the trade asso-

ciation, in particular the requirements laid out in DIN VDE 

0100. Furthermore, the national legal regulations applica-

ble in the respective country of use must be observed. 

 

‰

In the event of any defects such as loose connections or 

defective or damaged cables to the system, the product 

must not be put into operation. 

Содержание SunTop

Страница 1: ...ion of conformity see EC Declaration of Conformity All in Contents 1 Operating and assembly instructions 1 2 General information on these instructions 1 2 1 Standards and guidelines 1 2 2 Intended use...

Страница 2: ...the regulations on accident prevention environmental protection and occupational health and safety applicable at the location of use must be observed and adhered to The regulations and standards for...

Страница 3: ...l as inform his her customers regarding the operating and maintenance conditions for this product 3 4 General duties of the plant operator The plant operator is obliged to only operate the product in...

Страница 4: ...en out of operation immedi ately and the plant operator informed accordingly No changes conversions or attachments may be made to the product without the permission of the manufacturer The system must...

Страница 5: ...be implemented immediately after removing the SunTop from the original packaging The drive must be installed so that it cannot get wet Damage to the blind due to incorrect assembly Observe the notes...

Страница 6: ...ire is correctly connected Ingress of moisture will damage or even destroy the SunTop For devices with protection class IP44 the customer side connection of the cable ends or plugs cable feed through...

Страница 7: ...positions and deleting the relief function It is not possible to change or delete individual end posi tions This is always done in pairs upper and lower end position simultaneously When the end positi...

Страница 8: ...d Check mains voltage Allow drive to cool down 8 EN elero GmbH End position settings 5 6 7 Variant B Fixed upper end position lower end position freely adjustable Variant B Fixed upper end position lo...

Страница 9: ...s that can be reused if dis mantled by a specialist company Please note the local regulations on disposal of packaging materials and old appliances On disassembly additional dangers must be reckoned w...

Страница 10: ...44 44 Limit switch range revolutions 80 40 Operating time min S2 4 4 Length C mm 534 534 Length D mm 517 517 Length E mm 11 11 Weight kg 1 2 1 3 Thermal operating condition C 20 60 20 60 Conformity No...

Страница 11: ...er mm 50 50 50 50 50 50 50 Protection class IP 44 44 44 44 44 44 44 Limit switch range revolutions 40 40 40 40 40 40 40 Operating time min S2 5 5 5 4 4 5 4 Length C mm 466 466 526 526 516 546 546 Leng...

Страница 12: ...4 Rated current A 1 20 1 65 2 20 Rated power consumption W 280 380 490 Shaft diameter mm 63 63 63 Protection class IP 44 44 44 Limit switch range revolutions 80 40 40 Operating time min S2 4 4 4 Lengt...