3.
Assembly and connection
Work on the mains may be performed only by authorised
specialists
When connecting the wires for mains and protective low voltage
(sensors, external switches), VDE 0100 Part 410 and the assembly
instructions should be observed.
●
Switch off mains power
●
Connect as per wiring diagram
●
Fit light sensor, wind monitor and rain monitor as per Section 4,
fit following the relevant instructions
●
Clip terminal cover onto (8-pin) connecting terminal
●
The power unit is fixed in position using 2 expanding binders or
using mounting screws
●
Clip cover onto control panel (see series of diagrams below)
●
Plug on control panel
●
Switch on power
●
Set manual mode using "Auto On/Off” key. "Manual” appears on
the display (manual mode is set on delivery).
●
Using the
v
or
b
key, check direction of rotation of the motors.
Important
Key
v
sunshade system must retract
Key
b
sunshade system must extend
●
If the direction of rotation of the motors does not agree with the
v
and
b
symbols on the control panel, switch off power and
change over wires a
v
and
b
terminals of the power unit, then
switch power back on.
5
Series of diagrams for assembly
(representation applies to any
model)
1:
Cover
2:
Control panel
3:
Adapter frame
4.1: Frame
4.2: Bearing ring
5:
Power unit
6:
Terminal cover
7.1: Branch box
l
60, No. 13 701.5101
7.2: Surface socket, No. 24 843.0103 or No. 24 752.0001
Parts 4.2 and 7.2 replace parts 4.1 and 7.1 in the case of surface mounting.
Always put parts 1 and 2 together first when assembling
.