Fault
Cause
Remedy
Motor not running
L-P bridge missing
Pinch in L-P bridge
(p. 7)
Motor running in
Incorrect connection
Switch
▲
and
▼
wires on
wrong directuon
power unit (p. 6)
Motor fails to run
Intermediate position
Delete intermediate position
right to bottom
programmed
(p. 17)
Intermediate
1.) Sunshade system not 1.) Move sunshade system
position cannot be
in top end position (FTP) up and wait until “FTP”
programmed
symbol is displayed
(p. 17)
2.) Old intermediate
2.) Delete intermediate
position not deleted
position (p. 17)
3.) Manual mode not set
3.) Switch off automatic
(p. 11)
Intermediate
Sunshade system
Move sunshade system
position cannot
not in top end position
up and wait until
be deleted
(FTP)
“FTP” symbol is
displayed (p. 17)
Sunshade system
1.) Sunshade system
1.) Move sunshade system
does not run down, is not in top end
up and wait until “FTP”
although “sun”
position (FTP)
symbol is displayed
symbol is flashing
(p. 17)
2.) Automatic mode
2.) Switch on Automatic
not switched on
(p. 11)
3.) Delay time has not
3.) Wait for delay time
yet elapsed
(p. 12)
4.) Set temperature
4.) Wait for temperature
value not yet reached
to rise, possibly reduce
or switch of temperature
level (p. 12)
Sunshade system
1.) Set wind value
1.) Wait for wind to
goes up, although
exceeded
drop (p. 12)
the “sun” symbol
2.) Set temperature
2.) Wait for temperature
is flashing
value not reached
to rise, possibly reduce
or switch off temperature
level (p. 12)
Brightness value
Light sensor
Switch connections
in display for sun
connections are back
(p. 7)
is on 12, although
to front
sun is not
shining
System does not
Light sensor is shade
Position light sensor
extend in spite of
(too little sun)
elswhere
bright light
Troubleshooting