background image

Commissioning

Installation

Check whether a perfect radio connection exists between the
Lumero-868 and the receiver before installation at the desired
installation position.

Fix the Lumero-868 with the screws provided.

149,7

42

14,5

4,5

4,5

14,5

118,5

28

1,7

149,7

28

1,7

Vertical installation
position

Horizontal installation
position

Sensor
surface

n

Sensor
surface

n

Setting the threshold values

There is a solar multiple contact switch inside the Lumero-868.
The switch has several levels, which can be modified with a
small screwdriver.

Sun

Level 0 

Light function is deactivated

Level 1 

Move out at low light levels

Level 2 to E

Intermediate levels

Level 7 

Factory setting

Level F 

Move out in full sun

Check the set threshold value

Press the 

UP

or 

DOWN

button:

LED flashes 

Light value is higher (brighter) 
than set threshold value.

LED lights continuously

Light value is lower (darker) 
than set threshold value.

^

Deletion of a programmed Lumo-868

Press the       - und the       -button simultaneously.
The LED goes out. Wait until the LED lights again after approx.
3 seconds.
The Lumero-868 is deleted.

Check the sun protection function (test mode)

Condition:

The blind/shutter is retracted. 

The delay times are shortened in the test mode. You can then test
the travel movement of your system on the set light value being
exceeded or undercut.

1. Press the 

UP

button (wind symbol) for at least 3 seconds until

the red LED flashes.
The test mode stays active for 5 minutes but with the LED extin-
guished.

2. Shine a torch on the sun sensor.

Set light value is exceede 

W

shutter/blind immediately travels

out/down.

Set light value is undercut 

W

shutter/blind travels in/up after

15 seconds.

You can repeat the operation as often as you want within 
5 minutes.

In “normal” operation the LEDs light up every 5 seconds and show
that the threshold values have been reached or exceeded.

Warning!

Injury risk from extending the awning or running
down the venetian blind 

The test mode is active for 5 minutes. This time
cannot be shortened.
Keep away from the operating range of the system.

Note:  

The Lumero-868 must not be mounted under projecting
 structures.