Assembly
EN
4.2
Installation environment
CAUTION
Damage to the device by exceeding standard tolerances.
•
The steel construction must be designed to conform to the tolerances accor-
ding to DIN ISO 2768-1/-2 and ISO 13920 (B).
If the deviation in the steel construction is greater than the tolerances according
to DIN ISO 2768-1/-2 and ISO 13920 (B), this will require the deviation to be
compensated as follows by suitable building design measures by installation of
the device at the latest:
1. Mount the device in the steel construction in table position.
2. Increase the distance of the two top pick-up positions (e.g. fork) and install
a longer bolt.
3.
Fix the completely retracted device to the pivot mounting first and then to
the joint rod head.
4. Use the wide design of the top fastening to compensate for a centre offset
over the wider fork on the building with a longer bolt.