elero GmbH
EN | 15
14 | EN
Ⓒ
elero GmbH
4.4 Mechanical data
Mechanical data
Control module (ExitSafe-S) dimensions
67x40x22 mm
Control module (ExitSafe-S) weight
60 g
Battery pack (ExitSafe-A) dimensions
70x55x20 mm
Battery pack (ExitSafe-A) weight
168 g
4.5 Electrical connections
The ExitSafe is supplied with power via the spring clamp
(X1) on the control module with 230 V AC.
Designation
Assignment
L
External conductor
N
Neutral conductor
Table 1: Assignment power input
The control and supply of the motor to be connected via
the screw contacts (X2) on the ExitSafe control module.
No. Designation /
wire color
Assignment
1
-
black
0 V Motor Supply
2
+
white
+ 8.4 ... 12 V DC
motor supply
3
▼
red / brown
Signal DOWN/CLOSE
for motor
4
▲
brown / red
Signal UP for motor
Table 2: Assignment motor terminals
The ExitSafe is controlled by potential-free contact com
-
mand initiators. These are connected to the connector
strip (X3) on the control module. Control elements that
need to be supplied even in the event of a failure in the
mains supply can also be connected to this connector
strip.
Control elements
No. wire
color
Designa-
tion
Assignment
1
green
Individual ▲ Signal UP from
individual control
2
yellow
Individual ▼ Signal DOWN/CLOSE from
individual control
3
grey
Individual C
Common dimensions for
individual inputs
4
violet
Signal ▲
Signal UP from
master control or sensor
5
brown
Signal ▼
Signal DOWN/CLOSE
from master control
6 blue
Signal C
Common dimensions for
signal inputs