Adjustment instructions
Fault
Possible cause
Trouble shooting
• Radio teach-in mode does
• Faulty connection
• Check connection
not start
• Timer frame already expired (5 min)
• Interrupt mains voltage briefly
• Thermostat has triggered
• Allow drive to cool down
• Transmitter has no battery
• Check transmitter
(LED must be illuminated)
• Transmitter not in teach-in
• UP/DOWN button pressed too late.
• Restart radio teach-in mode
mode
Note timer frame (1 sec.)
• Drive stops briefly while
• Drive is in programming mode
• Program drive
running
• Drive runs brief distance only
• Shaft not driving pulling ring
• Set correctly and reprogram the drive
if necessary
• Drive not reacting to double
• Timer frame has already expired again
• Interrupt power supply briefly
button pressure with
after mains return (5 min)
• Check mains connection
radio transmitter
• Drive not on mains voltage
• End position gradually
• No approach to reference point for a long time
• Shut down the unit
changing
(approach to reference point)
• Not possible to program
• Drive is not in programming mode
• Program drive again
end position
• The upper reference point not reached
• Approach reference point
• Drive is no longer reacting
• Thermostat has triggered
• Allow drive to cool down
• The drive cannot be operated
• The DOWN button has been pressed before
• Erase the end position and
in the down direction after
the programming of the upper end position
programme it again
the programming of the
upper end position
elero
Auto
LR03 (AAA)
- -
UP
button
STOP
button
DOWN
button
UP
button
STOP
button
DOWN
button
Programming button
P
Programming button
P
20
www.elero.com
13 813.1001
Technical parameters subject to change 05/05