elero Aero-915 Скачать руководство пользователя страница 4

Maintenance

The Aero-915/Aero-915 Plus is maintenance-free, but the cover
must be cleaned from time to time.

Techncal Data

Power supply 

Solar

Temperature range 

–25 °C to +60 °C

Detection angle (light sensor)

150°

Protection class 

IP 43

Radio frequency 

915 MHz

Standby Aero-915

~  8 hrs.

Standby Aero-915 Plus

~ 16 hrs.

Fault

Cause

Remedy

• Awning automa-

tically retracts in
manual mode 

• No travel

command can 
be issued via the
manual trans-
mitter 

• Awning does not

retract in windy
conditions 

• Awning does not

move out in
sunny conditions

• Receiver does

not accept 
Aero-915/
Aero-915 Plus

• Wind alarm

• Poor radio connection 

• Wind alarm is active 
• Battery in the manual

transmitter is dead

• Motor has no power

supply or is overheated

• Wind threshold value is

set incorrectly 

• Wind vane is faulty

• Threshold set incorrectly 
• Wind alarm is still active 
• Manual mode is set 
• Poor radio connection 

• Sun sensor is dirty
• SUN threshold value

(OFF setting)

• Aero-915/Aero-915 Plus 

is already programmed.

• Wait for wind interlock

to be deactivated
(15 min.) or briefly
interrupt power supply.

• Change the position of

the Aero-915/
Aero-915 Plus

• Wait (15 minutes)
• Change battery
• Check power supply or

allow motor to cool
down.

• Set correct value 

• Replace

• Set correct value 
• Wait 
• Set automatic mode
• Change the position of

the Aero-915/
Aero-915 Plus

• Clean sun sensor 
• Set appropriate setting

• Delete Aero-915/

Aero-915 Plus.

20

18 100.6501

We reserve the right to make technical changes 06/06

20

elero USA

10827 Alder Circle
Dallas, Texas 75238

Tel. (1) 2 14/3 43-16 76
Fax (1) 2 14/3 42-85 28

[email protected]
www.eleroUSA.com

a

Wall bracket 
rotated 90° 

Wall bracket 
rotated 180° 

Mast and corner bracket  
(Aero, Aero-915/Aero-915 Plus)
Optional accessory
(Article no. 24 269,0201)

Mounting options for Aero-915/Aero-915 Plus

The wall bracket can be swivelled between –5° and 180°. 
Secure the required position once it has been set (see screw a).

Содержание Aero-915

Страница 1: ...erence e g hospitals airports The remote control is only approved for devices and systems for which any malfunction of the manual transmitter or receiver would not result in a risk for persons animals or property or if such a risk is covered by other safety devices The operator has no protection whatsoever from interferences by other radio emitters and local terminals e g also from radio installat...

Страница 2: ...ed transmitter 1 0 12 1 4 2 Off 8 4 6 1 1 1 3 9 5 7 1 0 12 1 4 2 Off 8 4 6 1 1 1 3 9 5 7 Setting the threshold values Multiple contact switches for wind and sun are located at the underside of the Aero 915 The switch has several settings which can be modified with a small screwdriver Wind Setting 1 Retract at low wind speed Setting 2 bis 10 Intermediate levels Setting 4 Factory setting Setting 11 ...

Страница 3: ...n as you want within 5 minutes In normal operation the LEDs light up every 5 seconds and show that the threshold values have been reached or exceeded Warning Injury risk from extending the awning or running down the venetian blind The test mode is active for 5 minutes This time cannot be shortened Keep away from the operating range of the system Check the wind function test mode Condition The blin...

Страница 4: ...e is set Poor radio connection Sun sensor is dirty SUN threshold value OFF setting Aero 915 Aero 915 Plus is already programmed Wait for wind interlock to be deactivated 15 min or briefly interrupt power supply Change the position of the Aero 915 Aero 915 Plus Wait 15 minutes Change battery Check power supply or allow motor to cool down Set correct value Replace Set correct value Wait Set automati...

Отзывы: