elero Aero-915 Скачать руководство пользователя страница 3

3

a

Wall bracket 
rotated 90° 

Wall bracket 
rotated 180° 

Mast and corner bracket  
(Aero, Aero-915/Aero-915 Plus)
Optional accessory
(Article no. 24 269,0201)

Caution!

Up- or downwinds blowing against façades may
cause destruction of equipment.

The Aero-915/Aero-915 Plus is 

not

able to recognise

these.

Please pay attention to this advice when choosing
your mounting position.

Deleting programmed Aero-915/Aero-915 Plus

The Aero-915/Aero-915 Plus is deleted from the receiver.

1.

Press the 

UP

/

and the 

DOWN

buttons 

simul-

taneously

.

10

12

14

2

Off

8

4

6

11

1

3

9

5

7

Green LED
(transmit)
goes out
briefly.

min. 3 sec.

Mounting options for Aero-915/Aero-915 Plus

The wall bracket can be swivelled between –5° and 180°. 
Secure the required position once it has been set (see screw a).

Check the sun protection function (test mode)

Condition:

The blind/shutter is retracted. 

The delay times are shortened in the test mode. You can then test
the travel movement of your system on the set light value being
exceeded or undercut.

1. Press the 

UP

button (wind symbol) for at least 3 seconds until

the green LED flashes.
The test mode stays active for 5 minutes but with the LED
extinguished.

2. Shine a torch on the sun sensor.  

Set light value is exceede 

W

shutter/blind immediately travels

out/down.

Light value has reached/exceeded the set threshold value 

W

yellow LED flashes.

Set light value is undercut 

W

shutter/blind travels in/up after 

15 seconds.

You can repeat the operation as often as you want within 
5 minutes.

In "normal" operation the LEDs light up every 5 seconds and show
that the threshold values have been reached or exceeded.

Warning!

Injury risk from extending the awning or running
down the venetian blind 

The test mode is active for 5 minutes. This time
cannot be shortened.
Keep away from the operating range of the system.

Check the wind function (test mode)

Condition:

The blind/shutter is retracted. 

The delay times are shortened in the test mode. You can then test
the travel movement of your system on the set wind value being
exceeded or undercut.

During the test phase the set wind value is automatically set to the
lowest value and re-set once the test phase (5 minutes) is over.

1. Press the 

UP

button (wind symbol) for at least 3 seconds until

the green LED flashes.
The test mode stays active for 5 minutes but with the LED
extinguished.

2. Use the hand transmitter to bring the shutter/blind to the

centre position.

3. Turn the wind vane.

The shutter/blind travels in/up immediately. 
Set wind value is exceeded/undercut 

W

red LED flashes.

You can repeat the operation as often as you want within 
5 minutes.

Note:

In the event of a wind alarm, the travel keys are disabled for
15 seconds.

In "normal" operation the LEDs light up every 5 seconds and show
that the threshold values have been reached or exceeded.

Warning!

Injury risk from extending the awning or running
down the venetian blind 

The test mode is active for 5 minutes. This time
cannot be shortened.
Keep away from the operating range of the system.

Installation

Before installing the unit at the required position, check the
proper function of the Aero-915 and the receiver.

Содержание Aero-915

Страница 1: ...erence e g hospitals airports The remote control is only approved for devices and systems for which any malfunction of the manual transmitter or receiver would not result in a risk for persons animals or property or if such a risk is covered by other safety devices The operator has no protection whatsoever from interferences by other radio emitters and local terminals e g also from radio installat...

Страница 2: ...ed transmitter 1 0 12 1 4 2 Off 8 4 6 1 1 1 3 9 5 7 1 0 12 1 4 2 Off 8 4 6 1 1 1 3 9 5 7 Setting the threshold values Multiple contact switches for wind and sun are located at the underside of the Aero 915 The switch has several settings which can be modified with a small screwdriver Wind Setting 1 Retract at low wind speed Setting 2 bis 10 Intermediate levels Setting 4 Factory setting Setting 11 ...

Страница 3: ...n as you want within 5 minutes In normal operation the LEDs light up every 5 seconds and show that the threshold values have been reached or exceeded Warning Injury risk from extending the awning or running down the venetian blind The test mode is active for 5 minutes This time cannot be shortened Keep away from the operating range of the system Check the wind function test mode Condition The blin...

Страница 4: ...e is set Poor radio connection Sun sensor is dirty SUN threshold value OFF setting Aero 915 Aero 915 Plus is already programmed Wait for wind interlock to be deactivated 15 min or briefly interrupt power supply Change the position of the Aero 915 Aero 915 Plus Wait 15 minutes Change battery Check power supply or allow motor to cool down Set correct value Replace Set correct value Wait Set automati...

Отзывы: