Mast support

As an alternative, mount the device to a mast of 27 mm 
diameter.

Corner or mast support

Use the corner or mast support to attach the device to the 
corner of the façade or to the mast.

Setting the mode (awning, protection 
against prying eyes, roller shutter)

The device can be operated in three different modes.
You can select the modes as follows:
1.  Turn the wind potentiometer to Function.
2.  Keep the UP and DOWN buttons pressed for at least 3 

seconds. Press the two buttons until the device is in the 
desired mode.

The 

fl

 ashing alarm LED indicates the mode of the device:

•  Red alarm LED 

fl

 ashes once 

 Awn

ing 

mode

•  Red alarm LED 

fl

 ashes twice 

 Protection against prying 

eyes mode

•  Red alarm LED 

fl

 ashes 3x 

 Roller shutter mode

The set mode is displayed at each radio transmission by the 

fl

 ashing of the operating LED  (LED 

fl

 ashing signal 1x per 

minute).
Turn the rotary potentiometer from Function back to a value 
selected by you.
The awning mode is set as standard in the delivery condition.
OEM versions may also be set to a different mode.

Note

Wind commands are executed in every mode.
The wind interlock is active for 15 to 17 minutes.

Awning mode

Requirement

 Twilight function is switched off. (Twilight potentiometer is on 
Off)

The awning will be retracted automatically when the current 
sensor measured value changes from 1 to 0 (late in the 
evening) or when the current light sensor measured value 
changes from 0 to 1 (early in the morning).

Protection against prying eyes mode

Requirement

 The light threshold value must be set to 2 or higher.

To keep the blind closed even in the evening, close the blind 
manually using a hand-held transmitter or an elero timer.
The current transitions of the light sensor measured values 
from 1 to 0 (late in the evening) or from 0 to 1 (early in the 
morning) will be ignored.
The blind will remain closed throughout the night. The 
travel commands such as tilting position (venetian blind) 
or ventilation position (roller shutter) will be executed 
automatically the next day.

Roller shutter mode

Requirement

The light threshold value must be set to 2 or higher.

Note

Support for the roller shutter mode is dependent on the 
software version of the receiver.

If the roller shutter is driven manually by a timer or the twilight 
function to the lower end position, the light function (driving 
according to set light value) will be switched off.
The current transitions of the light sensor measured values 
from 1 to 0 (late in the evening) or from 0 to 1 (early in the 
morning) will be ignored.
You can switch on the light function again in several different 
ways:
•  by means of a manual UP travel command to the upper end 

position

•  by means of an automatic timer command to the upper end 

position

•  by using the hand-held transmitter to switch from 

AUTOMATIC mode to MANUAL mode and back to 
AUTOMATIC mode.

Programming the device

Requirement

The end positions of the drive have been set. One transmitter 
has been programmed.

1.  Move the blind to the centre position.
2.  Press and hold the 

UP/DOWN

 and 

P

 buttons on the hand-

held/wall transmitter simultaneously for at least 3 seconds.

3.  Keep the STOP/P button pressed for 3 seconds until the 

green operating LED 

fl

 ashes fast. When the device is in 

programming mode, the operative LED 

fl

 ashes fast each 

time you press a button.

4.  The blind moves up and down for 2 minutes.

Setting the mode (awning, protection against prying eyes, roller shutter)

Содержание 28890.0006

Страница 1: ......

Страница 2: ...ll safety measures are observed and met The following safety and assembly instructions apply to the device and not to the accessories and drive Failure to observe these can cause physical injury Obser...

Страница 3: ...open opening retraction etc Up is used in accordance with the designation of the buttons Scope of supply Sensero 1 wall bracket 3 dowels 5 screws 1 nut Accessories Corner or mast support Item Number...

Страница 4: ...close the blind manually using a hand held transmitter or an elero timer The current transitions of the light sensor measured values from 1 to 0 late in the evening or from 0 to 1 early in the morning...

Страница 5: ...hed off Factory setting Level 1 Travel down at darkness Settings 2 to 13 Intermediate levels Level 14 Travel down at start of twilight Note The factory settings for OEM devices may differ from the abo...

Страница 6: ...traced The measured wind value exceeds the set threshold value the wind signal is triggered Blocked for 15 to 17 min The blind moves up and remains raised for a minimum of 15 to 17 minutes Red alarm L...

Страница 7: ...The set rain value is reached or exceeded Red alarm LED shines The blind travels up immediately Stop moistening the rain sen sor The set rain value is now undercut The red alarm LED flashes for 15 sec...

Страница 8: ...vice Light sensor is dirty Clean light sensor The device cannot be programmed to recognize the receiver Device is already pro grammed Delete the device and re program it Poor radio connection Change t...

Страница 9: ...ased sensor system Can be used in conjunction with controllers for opening and closing roller shutter and other shading systems as well as other actuators The conformity of the above mentioned product...