Page 13
Engineering Department PHONE: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: [email protected]
Back to index
Use and maintenance manual
2. USAGE INSTRUCTION
ELENOS
If the confirmation password is wrong the display will show:
IMPORTANT NOTE
! BE CAREFULLY !
Once the password is set, it must be remembered otherwise neither can
the frequency be changed or a new password entered.
Display Change of Frequency.
•
Press 3 seconds the SELECT key and put the correct password, at
this point press again the SELECT key:
•
Press the SELECT key to change the digit and press the SET key to
confirm the digit.
The underscore character move the position one place to the left.
STORED
NEW PASSWORD
ERROR
CONFIRMATION
NEW PASS . = SEL .
NEW FREQ . = SET .
FREQUENCY ?
MHz 300.000