7. Display Details
The
Auto (ranging)
annunciator is on when the meter is set
to a function that has multiple ranges available. The meter is
completely automatic and does not require the user to select
a range.
The
AC ~
annunciator is on when the meter is set to
measure AC voltage or current.
Negative Sign Annunciator
- This annunciator is displayed
when DC voltage being measured by the
V
Ω
Hz
jack is
negative in respect to the COM jack. It can also be displayed
in the A mode, when the measured current is in the
reverse direction of the polarity arrow. Note: Polarity arrow
indicates current flow from positive to negative.
Low Battery Annunciator
- This annunciator is displayed
when the battery needs to be replaced.
Hold Annunciator
- This annunciator is displayed any time
the hold mode is active.
REL Annunciator
- This annunciator is displayed whenever
the REL mode or the DCA ZERO-ADJ mode is active.
Continuity Annunciator
- This annunciator is displayed
whenever the Continuity (Beeper) mode is selected.
Diode Test Annunciator
- This annunciator is displayed
whenever the Diode Test mode is selected.
Percent Annunciator
- This annunciator is displayed
whenever the Duty Cycle mode is selected.
-8-
Auto
~
+
H
%