6. Care and Maintenance
6-1. Caring for Your Multimeter

Your digital multimeter is an example of superior design and craftsmanship.
The following suggestions will help you care for the multimeter so you can
enjoy it for years.
1. Keep the multimeter dry. If it gets wet, wipe it dry immediately. Liquids

can contain minerals that can corrode electronic circuits.

2. Use and store the multimeter only in normal temperature environments.

Extreme temperatures can shorted the life of electronic devices, damage
batteries, and distort or melt plastic parts.

3. Handle the multimeter gently and carefully. Dropping it can damage the

circuit boards and case and can cause the multimeter to work improperly
although the holster can provide enough protection.

4. Keep the multimeter away from dust and dirt, which can cause premature

wear of parts.

5. Wipe the multimeter with a damp cloth occasionally to keep it looking

new. Do not use harsh chemicals, cleaning solvents, or strong detergents
to clean the multimeter.

6. Use only fresh batteries of the required size and type. Always remove old

or weak batteries.

They can leak chemicals that destroy electronic

circuits.

6-2. Maintenance

Battery Replacement

1. Make sure that the instrument is not connected to any external circuit.

Set the selector switch to the OFF position and remove the test leads
from the terminals.

2. Remove the screws from the bottom case and lift the case. Remove the

spent batteries and replace them with batteries of the same type.

Fuse Replacement

Remove the screws from the bottom case and lift the case. Replace the
fuse with the same type and rating: 5 x 20mm 0.5A/250V fast-blow fuse
or 5 x 20mm 10@/250V fast-blow fuse as the replacements.

3. Features

• 9 Functions / 23 Measuring Ranges
• Surface Mounted PC Board Assembly
• Full Overload Protection
• Auto Power Off
• Tilt Stand
• Holster
• Low Battery Indicator

4. Specifications

4-1. General Specifications

Display

3 3/4 digit LCD with a max. reading of 4000.

Range Control

Manual range control (capacitance test is
auto range control).

Polarity

Automatic “      ” is displayed.

Zero Adjustment

Automatic.

Overrange Indication

“OL” on LCD is displayed.

Low Battery Indication

“        ” sign on LCD readout when the battery
voltage is below 2.4V.

Auto Power Off

Approximately 15 minutes.

Safety Standards

EMC/LVD.

The meter is up to the

standards of IEC1010 Pollution Degree 2,
Overvoltage Catagory II.

Operation Temperature

32

O

F to 104

O

F (0

O

C to 40

O

C)

less than 85% relative humidity

Storage Temperature

-4

O

F to 140

O

F (-20

O

C to 60

O

C)

less than 95% relative humidity

Power

2 x 1.5V “AAA” batteries.
(NEDA 1604)

Dimensions

5 15/16” (H) x 2 3/4” (W) x 1 1/2” (D)
(w/o holster)

Weight

Approximately 0.44 lb. (w/o holster)

Accessories

Safety Test Leads - 1 pair
Operator’s Manual - 1 pc.
Holster - 1 pc.

WARNING

Before attempting battery & fuse removal or replacement, disconnect
the test leads from any energized circuits to avoid hazard.

+

-5-

-12-

Содержание M-1750

Страница 1: ...onics Inc 150 W Carpenter Avenue Wheeling IL 60090 847 541 3800 http www elenco com e mail elenco elenco com OPERATOR S INSTRUCTION MANUAL M 1750 3 3 4 COUNT DIGITAL MULTIMETER Copyright 2003 ElencoTM Electronics Inc ...

Страница 2: ...re and Maintenance 12 6 1 Caring for Your Multimeter 13 6 2 Maintenance 13 WARNING PLEASE READ THIS INSTRUCTION MANUAL CAREFULLY Misuse and or abuse of this instruction cannot be prevented by any printed word and may cause injury and or equipment damage Please follow all these instructions and measurement procedures faithfully and adhere to all standard industrial safety rules and practices The mu...

Страница 3: ...aged or if you suspect that the meter is not operating properly Turn off the power to the circuit under test before cutting unsoldering or breaking the circuit Small amounts of current can be dangerous Use caution when working above 60VDC or 30VAC rms Such voltages pose a shock hazard When using the test lead keep your fingers behind the guards on the test lead Disconnect the live test lead before...

Страница 4: ...nt at which the voltage with respect to earth ground exceeds in this case 500 volts This symbol adjacent to one or more terminals identifies them as being associated with ranges that may in normal use be subjected to particularly hazardous voltages For maximum safety the instrument and its test leads should not be handled when these terminals are energized This marking indicates that equipment is ...

Страница 5: ... terminals 2 Remove the screws from the bottom case and lift the case Remove the spent batteries and replace them with batteries of the same type Fuse Replacement Remove the screws from the bottom case and lift the case Replace the fuse with the same type and rating 5 x 20mm 0 5A 250V fast blow fuse or 5 x 20mm 10 250V fast blow fuse as the replacements 3 Features 9 Functions 23 Measuring Ranges S...

Страница 6: ...ad to the COM socket and the red test lead to the VWHz socket 2 Set the selector switch to the Hz or Duty position 3 Connect the probes across the source or load under measurement 6 hFE Test 1 Set the selector switch to the desired hFE position PNP or NPN type transistor 2 Never apply an external voltage to the hFE sockets Damage to the meter may result 3 Plug the transistor directly into the hFE ...

Страница 7: ...ure that the circuit to be tested is dead Max input overload 250Vrms and 10sec 4 Capacitance Measurement 1 Before testing discharge the capacitor by shorting its leads together Use caution in handling the capacitors because they may have a charge on them of considerable power before discharging 2 Connect the black test lead to the COM socket and the red test lead to the VWHz socket 3 Set the selec...

Страница 8: ...art with the highest and work your way down 7 Extreme care should be taken when using the instrument in conjunction with a current transformer connected to the terminals if an open circuit occurs 8 Ensure that the test leads and probes are in good condition with no damage to the insulation 9 Take care not to exceed the overload limits as shown in the specifications 10 Before opening the case of th...

Отзывы: