background image

6. Maintenance

6-1. Battery Replacement

Replace the battery when “BAT” appears on the display.

1. Remove the two screws on the case cover. Then,

detach it from the top case.

2. Unsnap the battery from the connector and replace

it with a new 9 volt battery.

3. Close the case cover and secure it with the

screws.

1. Safety Information

To ensure that the meter is used safely, follow all of
the safety and operation instructions in this manual. If
the meter is not used as described in the manual, the
safety features of the meter might be impaired.

• Do not use the meter if the meter or the test leads look

damaged, or if you suspect that the meter is not operating
properly.

• Turn off the power to the circuit under test before cutting,

unsoldering, or breaking the circuit. Small amounts of current
can be dangerous.

• Use caution when working above 60VDC or 30VAC rms.

Such voltages pose a shock hazard.

• When using the test lead, keep your fingers behind the

guards on the test lead.

• Disconnect the live test lead before disconnecting the

common test lead.

• To avoid damage to the meter, do not exceed the input limits

shown below.

• This digital multimeter is designed for indoor use only.
Refer to Section 4-2 on page 6 for complete specifications.

FUNCTION

INPUT JACK

INPUT LIMITS

VDC

V/

& COM

1000VDC or 750Vrms AC

VAC

V/

& COM

600VDC or 750Vrms AC

/

/

V/

& COM

250Vrms @ 15 sec.

µ

A, mA DC

10A DC

mA & COM

10A & COM

250mA DC

10A DC

-14-

-3-

WARNING

Before attempting battery & fuse removal or
replacement, disconnect the test leads from any
energized circuits to avoid hazard.

+

Fuse

Содержание M-1000D

Страница 1: ...ectronics Inc 150 Carpenter Avenue Wheeling IL 60090 847 541 3800 Website www elenco com e mail elenco elenco com OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER M 1000D Copyright 2008 Elenco Electro...

Страница 2: ...screws from the back of the case 3 Remove the fuse from the holder and replace it with a new fuse of the specified value Fuse Numbers 250mA 250V Bussman Fuse GMA 250 250mA 250V Little Fuse 235 250 25...

Страница 3: ...off the power to the circuit under test before cutting unsoldering or breaking the circuit Small amounts of current can be dangerous Use caution when working above 60VDC or 30VAC rms Such voltages pos...

Страница 4: ...This marking indicates that equipment is protected completely be the double insulation 2 Introduction This meter is a 3 1 2 digit digital multimeter that is rugged reliable and convenient to use while...

Страница 5: ...the black test lead to the cathode 4 The forward voltage drop in mV will be displayed If the diode is reversed the number 1 will be displayed 3 Features 7 Functions 17 Measuring Ranges 0 25 Basic Acc...

Страница 6: ...dg 2dgt 10A 10mA 3 of rdg 2dgt OVERLOAD PROTECTION 250mA 250V fuse 10A range unfused MEASURING VOLTAGE DROP 200mV AC Voltage Measurement 1 Plug the red test lead into the V mA jack and the black lead...

Страница 7: ...3 Connect the test leads to the device or circuit being measured 4 Turn on the power of the device or circuit being measured The voltage value will appear on the digital display along with the voltage...

Страница 8: ...ing the unit in places with rapid temperature variations 4 In order to prevent damage or injury to the unit never fail to keep the maximum tolerable voltage and current especially for the 10A current...

Отзывы: