14
User Manual / NDA 100/3 TH(S) RG L20 230AC(PoE) LAN
Display settings
Display mode
Sensor No. 1 / Sensor No. 2 / Average from 2 sensors
Sensor No. 1
Display will show measured value from sensor No. 1 as configured above.
Sensor No. 2
Display will show measured value from sensor No. 2 as configured above.
Average from 2 sensors
Display will show average value from 2 sensors, if two sensors are connected.
Brightness mode Automatic
/
Direct
Automatic
Automatic control of brightness according to ambient light conditions,
via built-in light sensor.
Direct
Direct control of brightness via fixed brightness level entered by user.
Default factory setup is automatic.
Brightness level (1 – 100)
If
Direct
mode is selected above, this value sets fixed LED brightness level from 1 to 100.
Curve slope (1 – 100)
If
Automatic
mode is selected above, this value sets the slope of brightness regulation curve.
Display ID
1 – 247
Designates internal RS485 address ID number of display.
(MODBUS slave address.)
USB virtual serial COM port settings
Baud Rate
1200, 2400, 4800, 9600, 14400, 19200, 38400, 57600, 115200.
Baud rate for USB communication interface (default: 19200 Bd)
Parity
None,
Even,
Odd
Parity type settings for USB interface (default: EVEN)
MODBUS RS-485 Serial Settings
Baud Rate
1200, 2400, 4800, 9600, 14400, 19200, 38400, 57600, 115200.
Baud rate for RS485 communication interface (default: 19200 Bd)
Parity
None,
Even,
Odd
Parity type settings for RS485 interface (default: EVEN)
MODBUS TCP/IP Settings
MAC
Shows MAC address of connected display.
User cannot change this field.
IP address
Shows IP address of display (same IP address as in the URL field of the browser).
Factory default IP address is on the label located on the back panel of display.
Enter new IP address according to your LAN setting.