background image

2 2

Appendix A 

I N S T A L L A T I O N   M A N U A L   |

Problem

Possible Cause

Solution

G

The pilot light goes 

on but goes out 

immediately when 

the main burner 

switches on

1

Insufficient voltage across the thermocouple or 

too much resistance in the thermocouple circuit

Place the measuring pins of the multimeter on the ground and 

black cable of the breaker. This value must be at least 4.5 mV.

Tip:

 For this action a video is available on our youtube channel

2

Gas pressure loss may cause the pilot flame to be 

too small

Check and measure the pre-pressure via test point A (See 

Figure 

A.D

)

Tip 1:

 Measure the pre-pressure load and unloaded

Tip 2: 

For this action a video is available on our youtube channel

3 Thermocouple defect 

Replace thermocouple

Tip:

 Always use a new pressure piece when a thermocouple is 

replaced

4 Thermocouple is incorrectly positioned

Check the position of the second thermocouple. 
(See 

Figure A.G

)

H

Check the position 

of the second 

thermocouple. (See 

Figure A-7)

1 Decoration material blocks 2nd thermocouple

Leave the space around and at the 2nd thermocouple free of 
decorative material. (See 

Figure A.H

)

2

Burner grille does not fit well with the 2nd 

thermocouple

Position burner grate

3

Airflow in the burner chamber causes a restless 

fire image

Check drain configuration

Fit a flue gas limiter

I

Receiver gives 3 

short beeps after 

each command:

1 Batteries in the receiver are empty

Replace the batteries4x 1.5V AA 

J

Pilot is on but the 

main burner does 

not start working:

1 Gas valve is on manual

Set Knob A must be in the ON position (see 

Figure A.1

). 

K

Double burner does 

not work:

1 RESET the receiver

Briefly press the RESET button and the receiver sounds 1 beep 

(See 

Figure A.J

)

2 Wiring loose on the receiver

Click the plug in the AUX position on the receiver.
(See 

Figure A.K

)

3

Solenoid valve does not switch

Replace the solenoid valve.

Tip: Only connect a new valve to the receiver first

4 Remote defective.

Check if the AUX symbol is on the display when you press the 
PLUS PLUS key on the remote. (See 

Figure A.L

)

L

No response from 

the receiver when 

the fireplace 

is started via 

smartphone or 

tablet. 

Disconnect the Wi-Fi box from the receiver
Click the plug from the SI connection on the receiver (See 

Figure 

A.M

)

Tip: 

Reset the home router

If the fireplace now functions normally, check the Wi-Fi settings

M

Hearth does 

not respond via 

Domotica system

Disconnect the cabling on the Domotica system and start the fire 

with the hand transmitter

When the fireplace now reacts normally, the problem is in the 

Domotics

Содержание Summum 100

Страница 1: ...INSTALLATI O N MA NUAL INSTALLATI O N MA NUAL Please leave these instructions behind with the device S U M M U M 1 0 0...

Страница 2: ...INSTALLATION MANUAL i Do not use this product as a primary heat source...

Страница 3: ...8 6 1 FIRE SAFETY DEVICE SET UP 8 6 1 1 PROTECTION OF WALL AND CEILING 8 6 2 ASSEMBLY REGULATIONS 8 6 2 1 GENERAL ASSEMBLY REGULATIONS 8 6 2 2 ASSEMBLY REGULATIONS FOR NON FLAMMABLE MATERIALS 8 6 2 3...

Страница 4: ...11 3 3 SOUND CHECK 19 A TROUBLESHOOTER 20 A A FIRST AID FOR MALFUNCTION 20 A B NECESSARY TOOLS 24 B ERRORS CODES PROCONTROL APP 25 B A MESSAGES SHOWN IN APP 25 B B MESSAGES SHOWN IN REMOTE 26 C FAULT...

Страница 5: ...mounted to the device Make sure it is accessible at all times This device may not be used a primary heat source This device is designed to be used with natural gas or LPG The device can only be used w...

Страница 6: ...sembly error or material defect Element4 will provide a free replacement part to the installer without compensation for disassembly or montage 5 In case the installer is not able to fix the problem hi...

Страница 7: ...ON 1 2 OFF Figure 4 1 Remote and ignition sign Figure 4 2 Top and side view of the Receiver 4 2 IGNITING THE PILOT LIGHT Check that the control knob A is in the ON position Figure 4 3 Press the button...

Страница 8: ...e in the near vicinity of the device Position the gas connection such that it is always accessible for service purposes The gas block and receiver are under the combustion chamber in the deivce so tha...

Страница 9: ...objects e g built in furniture or wooden panels are mountedonthesideofthewallthatisturnedawayfromthefireplace For these types of installations please refer to CHAPTER 6 2 3 CHAPTER 6 2 3 6 2 ASSEMBLY...

Страница 10: ...fireplace 200 C Table 6 1 Legenda 6 7 21 6 6 7 21 6 E d3 D F G I d1 H A2 B C d2 6 7 21 6 RQ 5 1 339 0 4 81 66 27 5 6 63 0 16 216 5 1 0 0 7 56 685 1 6 72 5 1 6 1 5 1 8 5 1 6 855 1 5 6 53 6 1 0 6 1 785...

Страница 11: ...ure ventilation opening are necessary Figure 6 5 The ventilation grills are to be placed at a minimal distance of 20cm from the ceiling and 30cm from any built in furniture from the side any flammable...

Страница 12: ...terminal see APPENDIX E APPENDIX E you search for the corresponding calculation tables Each category refers to a set of tables 1 A table for horizontal outlet 2 A table for vertical outlet You must u...

Страница 13: ...Follow the following instrucions for the installation of flue materials Drill a hole of 160 mm for the wall or roof transit with a 150 mm diameter flue connection and 210 mm with a flue with a diamet...

Страница 14: ...one week to ensure yourself of an optimal desired room temperature Also the device can changed between high and low flames and it features an eco setting The amount of users that can operate the devic...

Страница 15: ...section The trays can be easily removed for maintenance The trays must be filled with the supplied glass crystals Divide the glass evenly over the bottom so that the light is well broken Cover the gl...

Страница 16: ...glass To do this follow these steps Check whether the trims are removed in as in step 10 1 1 Remove the ropes holding the glass See Figure 9 6 Put the section cup on the glass and make sure it is pro...

Страница 17: ...er 9 INSTALLATION MANUAL Figure 9 2 Remove screws from the top trim Figure 9 3 Remove top trim Figure 9 4 Remove side trims Figure 9 5 Remove bottom trim Figure 9 6 Remove glas rope Figure 9 7 Remove...

Страница 18: ...lso be unnecessary If this is the case check the burner pressure at the inlet to the burner The instructions of changing the burner pressure and the correct pressure per gastype can be found in 9 3 2...

Страница 19: ...rrangement reseal the appliance and check the safe operation of the appliance 10 DECORATIVE CERAMIC PARTS This appliance is equipped with a ceramic fire bed with heat resistant ceramic fibers or artif...

Страница 20: ...ble plus button to switch between burners Flames and soot During this first fire examine the flame for appearance and quality Flames may appear blue at first but will turn yellow after 15 to 20 minute...

Страница 21: ...turbs the reception Change the position of the antenna See Figure A B C No ignition no beep 1 Receiver defective Reset the receiver See K1 If necessary replace the receiver D No ignition receiver give...

Страница 22: ...Appendix A INSTALLATION MANUAL Figure A A Bend pin Figure A B Antenna Figure A C Torx screw Figure A D Testpoint 4 5 mV 4 5 mV Figure A E Interrupter Figure A F Wiring receiver 40mm Figure A G Pilot s...

Страница 23: ...ouple Position burner grate 3 Airflow in the burner chamber causes a restless fire image Check drain configuration Fit a flue gas limiter I Receiver gives 3 short beeps after each command 1 Batteries...

Страница 24: ...Aux position receiver AM PM ON 1 2 OFF Figure A L Double plus button on the remote Figure A M SI port PANEL G60 ZCE 1000 MA GR MO SW 2 1 3 MODE Ignition Main Burner High Flames Pilot Extinguish Main...

Страница 25: ...ed Please note If a problem is found that cannot be solved on site always contact your dealer or directly contact Element4 via our credentials which can be found on the back page of this manual 00 00...

Страница 26: ...eeps for 3 sec during motor turn Low Receiver battery power supply F10 Contact Service Pilot lit Main burner fails to ignite and pilot shuts off Ignition is blocked for 2 minutes 2nd thermocouple is o...

Страница 27: ...mmunication between Receiver and myfire Wi Fi Box F44 Contact Service No temperature shown in App N a not applicable displayed in App Handset not within range Low battery power in handset F49 Contact...

Страница 28: ...istances from occurring Many people put the router in the meter cupboard because that is where the internet comes in at many households A bad choice For a powerful WiFi signal the router needs as much...

Страница 29: ...NAL LOCATION WITH VERTICAL EXHAUST C11 Distance Exhaust 1 2 of 3 At the same roof level 6m At a different roof level 3m On a lower wall 2m On a higher sloping surface 6m Distance minimum distance requ...

Страница 30: ...O O O O O O O O V 9 O O O O O O O O V 8 O O O O O O O O V 7 O O O O O V V V V 6 O O O O O V V V V 5 O O O O O V V V V 4 O O O O O V V V V 3 5 O O O O O V V V V 3 V V V V V V V V V 2 5 V V V V V V V V...

Страница 31: ...n 2x 320 log 1x 120 Main 2x 140 log Type of flue C11 C31 C91 Additional electricity use At rated heat output elmax 9 5 kW With minimal heat emission elmin 9 5 kW In stand by mode elsb 9 5 kW Power req...

Страница 32: ...ays supplied with the fireplace The ecolabel shows which category the fireplace belongs to G A ECOLABELS The ecolabels for the different types of gas are indicated below respectively G20 G25 and G30 1...

Страница 33: ...f the Fireplace with some of the important dimensions that you have to take into account when installing and installing your fireplace 199 00 134 00 570 00 1000 00 829 00 162 70 105 00 1091 00 1008 00...

Страница 34: ...N MANUAL 199 00 134 00 575 00 1000 00 829 00 162 70 105 00 424 00 61 00 48 50 1102 00 1047 00 61 50 62 00 119 05 51 50 575 00 328 00 556 50 51 50 66 57 119 05 Figure H B Dimensional drawing of the Sum...

Страница 35: ...ndix H INSTALLATION MANUAL 199 00 134 00 575 00 1000 00 829 00 162 70 105 00 424 00 61 00 48 50 1116 00 62 00 61 50 575 00 328 00 556 50 51 50 66 57 119 05 Figure H C Dimensional drawing of the Summum...

Страница 36: ...Info element4 nl www element4 nl 24 05 22 ELEMENT 4 B V Design Assembly by RELEASE DATE...

Отзывы: