2 Important safety information

The fireplace may only be installed by a qualified installer/dealer, 

following these installation instructions. We advise you to read 

these instructions properly, before commencing the installation 

of your device. 

Before installation check the decive for transport damage and 

inform your supplier immediatly if damage is found. 

Check the data on the dataplaat. The gas type and pressure 

should check out with those locally available. The data plate is 

mounted to the device. Make sure it is accessible at all times.  

This device is design to be used with natural gas or LPG. The 

device can only be used with the type of gas specified on the 

data plate at the time of purchase. 

The device may never be used without the glass of when glass 

is broken. The flue gasses can get into the installation room. The 

settings and construction of the device must not be changed! 

Parts are only to be changed with original parts by the original 

manufacturer. 

The device is provided with a special set of decorative materials. 

Do not place any extra imitation logs or decoration material on 

the burner or in the combustion chamber. See chapter 11 for an 

instruction on how to arrange the decoration properly. 

The glass and frame on this appliance acts as a fireguard 

conforming to BS: 1945 – 1971 and satisfies the Heating Appliance 

(Fireguards) regulations 1991. No part of the window or frame 

should be permanently removed. It does not give protection for 

young children aged or infirm, extra guarding (conforming to 

BS8423: 2002) should be considered so the special hazards that

exist in nurseries and other places where there are young 

children, aged or infirm persons are minimized.

The heat that is coming from the device may effect the materials 

in its surroundings. Always take into account to correct safety 

distances. For more information see chapter 6. 

1 CE statement 

We hereby declare that the design and construction of the 

Element4 gas appliances are complying to the essential 

demands and regulations for gas products. 

Product: 

• 

Gas fireplace, local spaceheater 

Model: 

E4-18  

• 

Modore 75H 

Applicable EG-guidelines: (EU) 2016/426 (GAR)

Applicable harmonized norms: 

• 

NEN-EN-613

• 

NEN-EN-613/A1

This declaration loses its validity when changes to the device are 

made without the written permission by Element4. You can ask 

for a copy of the test certificates of all models via our general 

e-mail adress, which is found on the back of this manual. 

J. Kempers

CEO

Содержание Modore 75H

Страница 1: ...ND WITH THE DEVICE Element4 Modore 75H INSTALLATION USER MANUAL W A R N I N G T H E CO M B U ST I O N C H A M B E R O F T H I S STOV E S H O U L D O N LY B E O P E N E D A N D S E RV I C E D BY A R E...

Страница 2: ...INSTALLATION MANUAL 2...

Страница 3: ...INSTALLATION MANUAL 3 THIS PRODUCT IS NOT SUITED FOR USE AS A PRIMAIRY HEAT SOURCE...

Страница 4: ...4 INSTALLATION MANUAL...

Страница 5: ...9 Elektrical circuit 13 9 1 Domotica 13 9 2 Element4 ProControl App 13 10 Maintenance instruction 14 10 1 Maintenance in the combustion chamber 14 10 2 Cleaning the glass 14 11 Decoration arrangement...

Страница 6: ...r in the combustion chamber See chapter 11 for an instruction on how to arrange the decoration properly The glass and frame on this appliance acts as a fireguard conformingtoBS 1945 1971andsatisfiesth...

Страница 7: ...by a competent installer according to the rules and regulations that are applicable in the country or even region of installation and those as described in this manual 2 There is a warranty period of...

Страница 8: ...on Fig 4 2 Within 20 seconds press the down arrow on the remote control until you hear a sound signal This is confirmation of the proper communication 4 2 Igniting the pilot light Checkthatthecontrolk...

Страница 9: ...gas flue such that no pressure loss is occuring in the pipes Place a shut off valve in the near vicinity of the device Position the gas connection such that it is always accessible for service purpose...

Страница 10: ...the device or chimney The device must never be placed against a back wall of flammable materials Flammable materials such as wood can combust at a temperature of 85 C At high temperatures this can ha...

Страница 11: ...mm to ensure a convection air flow Make sure there is a good air ventilation in the cove The temperature that leaves through the ventilation grilles must not be higher than 85 C Therefore one should...

Страница 12: ...arding you flue gas configuration a casing is necessary For this case non combustible materials should be used Make sure to ventilate a shaft and never to insulate it to make sure the hot air is able...

Страница 13: ...le fire are installed in the same location Another functionality of the app is to pre set the temperature of you device for a period of one week to ensure yourself of an optimal desired room temperatu...

Страница 14: ...p 10 1 1 Remove the cords that hold the glass See Figure 10 4 Put the section cup on the glass and make sure it is properly vaccuumed so it will not come off fig 10 5 Lift the glass for a little bit a...

Страница 15: ...15 INSTALLATION MANUAL Afbeelding 10 6 Removing glass Afbeelding 10 5 Put on the suction cups Afbeelding 10 4 Removing cords Afbeelding 10 3 Removing lower trim Afbeelding 10 2 Removing side trims...

Страница 16: ...e slots on the Burner The Pilot flame must be visible through the grate and the cut out in the Pilot Shield Ensure that a number of holes in the Grate and the Pilot area are free of embers After placi...

Страница 17: ...iances 12 User Instruction We recommend that you have the appliance inspected annually by a recognized installer to ensure safe use and a long service life guarantee 12 1 Hand over to the customer Use...

Страница 18: ...as appliances must always be installed by a competent installer in accordance with national and if applicable regional standards and according to the installation instructions supplied with the applia...

Страница 19: ...19 INSTALLATION MANUAL...

Страница 20: ...he reception Change the position of the antenna See Figure A 2 C No ignition no beep 1 Receiver defective Reset the receiver See K1 If necessary replace the receiver D No ignition receiver gives a fiv...

Страница 21: ...21 APPENDICES 40mm Figure A 7 Pilot set 4 5 mV 4 5 mV Figure A 5 interrupter Figure A 1 Bend pin Figure A 2 Antenna Figure A 6 Wiring receiver Figure A 3 Torx screw Figure A 4 Testpoint A...

Страница 22: ...Position burner grate 3 Airflow in the burner chamber causes a restless fire image Check drain configuration Fit a flue gas limiter I Receiver gives 3 short beeps after each command 1 Batteries in th...

Страница 23: ...igure A 8 Second thermocouple Figure A 9 Button A on On A Figure A 13 SI entrance Figure A 11 Aux position receiver Figure A 10 RESET button Figure A 14 Domotica system Figure A 12 Doubble plus button...

Страница 24: ...service 5 sec beep No reaction from the fireplace and no ignition 2nd thermocouple not connected Wiring 2nd thermocouple F16 Hand transmitter out of reach No temperature in the app Hand transmitter ou...

Страница 25: ...he pipe No spark F09 F09 4 sec No reaction from the fireplace No electronic control The torque of the hand transmitter and receiver did not work F40 Battery symbol Contact service Continu Battery volt...

Страница 26: ...stances from occurring Many people put the router in the meter cupboard because that is where the internet comes in at many households A bad choice For a powerful WiFi signal the router needs as much...

Страница 27: ...bove the intersection with the roof 150 D Location terminal Distance minimum distance required to position the exhaust in order to prevent adverse effects in relation to 1 A ventilation opening of a u...

Страница 28: ...ve tapered your flue gas extraction as per the above to a diameter of 150 100 then the total maximum permitted vertical length of your flue gas extraction is 11 meters If you are using a diameter of 2...

Страница 29: ...V THG 0 0 5 1 1 5 2 2 5 3 22 0 x x x x x x x x 21 35 35 0 x x x x x x 20 35 35 35 35 0 x x x x 19 35 35 35 35 35 35 0 0 0 18 35 35 35 35 35 35 0 0 0 17 35 35 35 35 35 35 0 0 0 16 35 35 35 35 35 35 0 0...

Страница 30: ...0 max Heat output kW 10 8 10 8 10 8 10 0 10 8 10 0 10 7 min Heat output kW 3 6 3 6 3 6 3 3 3 6 3 3 3 6 Max Gas usage m3 uur 1 25 1 25 1 25 1 34 1 2 1 34 0 36 NOx mg kWhinput 100 100 Pilot 440 1350 31...

Страница 31: ...eplace belongs to H 1 Ecolabels The ecolabels for the different types of gas are indicated below respectively G20 G25 and G30 Bioptica A A B C D E F G 2015 1186 kW ENERGIA ENERGIJA ENERGY ENERGIE A A...

Страница 32: ...ge and the following ones you will find dimensional drawings of the Cupido models and accessories with some of the important dimensions that you have to take into account when installing and installin...

Страница 33: ...33 APPENDICES 172 933 656 880 458 760 2 0 0 1 3 0 380 427 442 754 754 754 950 651 925 716 754 150 min Afbeelding I 2 Technical drawing Modore 75H...

Страница 34: ...34 APPENDICES...

Страница 35: ...35 APPENDICES...

Страница 36: ...Paxtonstraat 23 8013 RP Zwolle The Netherlands Info element4 nl www element4 fires com ELEMENT 4 B V APRIL 2018...

Отзывы: