29
ENCLOSING the FIREPLACE
Element4 Gas Fireplaces Rev# 07022020
European
Home
.com
MINIMUM AREA REQUIRED FOR THE TENORE 240 MKII GSB FIREPLACE
FRO
NT S
TAN
dO
FF F
RAM
E M
uST
bE F
LuS
h T
O T
hIS L
INE
There is a minimum clear area which must be maintained when enclosing the Tenore 240 MKII GSB fireplace. Nothing except the Tenore
240 MKII GSB
cabinet
may be within this area. Inside this space, the Tenore 240 MKII GSB must be centered, left to right, and the faces
of the two stand-off frames must be 20”/508
mm
from the each other. This minimum area
MUST BE ENCLOSED BY NON-COMBUSTIBLE
MATERIAL
. The
inside
of the enclosing walls (including any necessary framing) may be no less than the distances shown above.
Your installation
will
use more than this minimum cabinet space in order to accommodate controls, venting, air openings, etc. We
recommend that the fireplace be set into its final location before building the enclosure.
Letter Inches Millimeters
A
20
508
B
1089/16
2757
C
48
1219
REA
R ST
ANd
OFF F
RAM
E M
uST
bE F
LuS
h TO T
hIS L
INE
Figure 42