10
SPECIFICATIONS and DIMENSIONS
Element4 Gas Fireplaces Rev# 03242020
European
Home
.com
APPLIANCE RATINGS
Mode
l
Lucius 140 RD MKII GSB
Lucius 140 T MKII GSB
Gas
Natural Gas
Propane
Input Maximum
Btu/hr
37,534
39,240
Input Minimum
Btu/hr
7,507
7,848
Maximum Supply
Pressure
in. w.c.
10
12
kpa
1.74
2.99
Minimum Supply
Pressure
in. w.c.
4
8
kpa
2.49
2.0
Manifold Pressure
Maximum
in. w.c.
5.4
11.4
kpa
1.34
2.84
Manifold Pressure
Minimum
in. w.c.
0.4
1.5
kpa
0.1
0.38
Main Burner Injector Marking
650 (x2)
280 (x2)
Pilot Injector Marking
32.2
27.1
New Efficiency
89%
A typical rating label is shown above. It is attached to every
Element4 fireplace and contains important certification
information.
It must not be removed from the fireplace.
Figure 2
Figure 3