44
OPERATING the FIREPLACE
Element4 Gas Fireplaces
European
Home
.com
BEFORE THE FIRST FIRE
1. Make certain that all construction materials have been removed from inside and around the fireplace and the fireplace has
been cleaned of any construction dust. Clean the glass BEFORE and AFTER the first fire.
2. Confirm that the gas valve is properly connected and bled by a certified gas technician or plumber.
3. Check the gas supply for leaks and proper pressure. --- Refer to the table in “Appliance Ratings” section.
4. Check that the venting is unobstructed and in proper working condition.
5. PROPERLY PLACE, CLAMP, AND SEAL THE GLASS PANELS.
6. Ensure the receiver is plugged in with AC Adapter
OR
Batteries...
NOT BOTH
.
7. Place the (2) AAA batteries into the remote control and confirm that it will communicate with the receiver by pressing the
ON
/
OFF
button. If necessary pair the remote and receiver.
8. Follow
USING THE REMOTE CONTROL ELECTRONIC IGNITION SEQUENCE
to setup and use remote.
PAIRING THE REMOTE AND RECEIVER
(System Reset)
From the factory, the remote control will communicate with the receiver; they are ‘paired’ and should need no further attention. If
the receiver does not respond to commands from the remote they should be paired to each other. This is done as follows:
1. Press and hold the receiver reset button using a small, long tool until you hear the second of two beeps. After the second
beep release the reset button.
2. Press and hold the button on the remote until you hear the second of two beeps. Release the button.
If you hear one long beep, this indicates the pairing sequence has failed or the wiring is incorrect.
RESET
BUTTON
(This knob is AUTOMATIC and will turn
off when the fireplace is turned off &
on when the fireplace is turned on.)
Note!
For normal operation the
MANUAL
knob on the gas valve cannot be in the
MAN
position; it must be fully in the
ON
position.
MANUAL
KNOB IN
ON
POSITION
MAIN VALVE
KNOB
IN
ON
POSITION