CLEARANCES
Element4 Gas Fireplaces Rev #05112020
European
Home
.com
TYPICAL CLEARANCE DIAGRAMS
The total area of the air openings must be maintained. The location of the openings must allow for the free movement of air and
must not allow excessive warm air to build up within the chase.
The top of the Air Outlet must be
no more
than 1” (25 mm) down from the
chase
ceiling.
The minimum distance from the bottom of the appliance to the room ceiling is 72” (1830
mm)
.
Minimum Required Air Opening Sizes
Air Inlet
Air Outlet
Model
Square
Inches
Square
Centimeters
Square
Inches
Square
Centimeters
Tenore 100 GSB
Lucius 100I GSB
145
936
145
936
Minimum Distances
A
Room ceiling to
appliance bottom
72”
1830
mm
B
Chase ceiling to top
of Air Outlet
1”
25
mm
B
B
A
Air Outlet
Figure 17
Figure 18
Figure 19