INSTALLATION METHOD
This product has been designed to be free-standing. If the product is
to be installed into an open chimney or flue, it is important that the
chimney flue is blocked off to prevent any up/down draughts and falling
debris which could restrict the airflow to the product.
7�1
PRODUCT SIZE
The Ovation-e has the following dimensions to keep into account
(WxHxD):
825 x 865 x 325 mm.
It is also important to ensure that the product has a minimum clearance
around it of 15mm, this is to ensure that the product can circulate the
required airflow to the heater unit.
The product should never be sealed into an opening with the use of
silicones or adhesives as this can alter the airflow and hinder any further
servicing of the product.
Please refer to technical specification table for further information, with
reference to measurements.
6
INSTALLATION REQUIREMENTS
If the product is to be installed into an open chimney or flue, it is
important that the chimney flue is blocked off to prevent any up/down
draughts and falling debris which could restrict the airflow to the product.
It is also important to ensure that the product has a minimum clearance
around it of 15mm, this is to ensure that the product can circulate the
required airflow to the heater unit.
The product should never be sealed into an opening with the use
of silicones or adhesives as this can alter the airflow and hinder any
further servicing of the product.
Please refer to technical specification table for further information, with
reference to measurements.
6�1
HEATER UNIT CUT OUT
This is a safety feature to safe guard against further damage to the product.
If the airflow is restricted the heater will automatically turn off. This can
occur due to incorrect installation or obstruction. To reset the heater
function;
•
Isolate from main power supply
•
Leave product to cool
•
After suitable cooling down period, remove the obstruction if
obstructed and check installation
•
After 10 minutes the thermo switch (cut-out) in the heater will
reset.
Please note
that both the effect fan and heater fan omit a low decibel
noise, both of which are normal operating characteristics.
6�2
SERVICING
Only a competent person should service this appliance.
This appliance must be serviced every 12 months.
Warning
: Before carrying out any repairs or servicing, ensure that the