Element4 E4-35 Скачать руководство пользователя страница 19

1 8

Chapter 11 

I N S T A L L A T I O N   M A N U A L   |

11 

OPERATING THE FIREPLACE

11�1 

BEFORE THE FIRST FIRE 

1. 

Make sure the cables of the ignition are hanging loosely under the 

device, to ensure a good ignition. Remove any tie wraps or other 

cable binders. 

2. 

Make certain that all construction materials have been removed 

from inside and around the fireplace and the fireplace has been 

cleaned of any construction dust. 

3. 

Clean the glass BEFORE and AFTER the first fire on both sides of 

the glass.

4. 

Properly place, clamp and seal the glass  panels. 

5. 

Ensure the receiver is powered with an AC Adapter OR Batteries, 
but not both!

6. 

Place the two (2) AAA batteries into the remote control and 

confirm that it will communicate with the receiver by pressing the 
ON/OFF button. 

7. 

Check the pilot and second thermocouple for obstructions

8. 

Check the air tightness of the system. 

More technical specifications can be found in 

APPENDIX F

APPENDIX F

.  

11�2 

THE FIRST FIRE

When  the  fireplace  is  fired  for  the  first  time,  one  should  check  the 
behaviour of the fireplace to see if all is functioning well. 

Should  any  problems  occur  during  first  firing  a  troubleshooter  can  be 

found in 

APPENDIX A

APPENDIX A

 for the gas parts and 

APPENDIX B

APPENDIX B

 provides an 

overview of possible error codes in the remote control. 

11�3 

SENSORY CHECKS

11�3�1 

VISUAL CHECKS

Condensation 

When the glass is cold, some condensation may appear on the glass after 
lighting the fireplace. This is normal as the combustion air contains a little 

water and the product of the gas being burned is not yet evaporating. 
The condensation will disappear as the glass warms.

To  ensure  as  little  condensation  as  possible  and,  as  an  additional 
benefit, to decrease the release of solid nitrogen oxide particles which 
are  bad  for  the  environment,  the  fireplace  will  start  on  just  the  main 
burner. During the first minute of firing this will ensure your fireplace 

to evaporate the condensation on the glass and heat up the air in the 
combustion chamber. 

Please note: 

During  the  first  minute  of  firing  i.e.  the  initial  start  up 

sequence of lighting the pilot flame and the first 30 seconds until the 
second thermocouple has given its clear, it is not possible to use the 
'double plus'-button to switch between burners.

Flames and soot

During  this  first  fire,  examine  the  flame  for  appearance  and  quality.  
Flames  may  appear  blue  at  first,  but  will  turn  yellow  after  15  to  20 

minutes. 

Examine the logs for sooting. Too yellow (near orange) flames indicate a 

problem with the combustion air. Clear black soot may then settle on the 

decoration material. When this is the case, you may contact your dealer. 

This fireplace has a 2nd thermocouple saftey system, which senses the 
burner flame. The system will turn itself off if the system does not sense 

the 2nd thermocouple output within 29 seconds after the valve opens.

Coating 

When firing up the device for the first time, make sure the device burns 
for several hours on the highest level, to ensure the lacker to harden. If 
an  enclosure  has  not  yet  been  constructed,  these  fumes  may  also  be 
visible around the fireplace.  

Because a fireplace is a heat source, natural convection will occur around 

it. Solid particles in the circulating air may burn and settle down on cold 

surfaces,  causing  discoloration.  Discoloration  is  an  annoying  problem 
and it is difficult to solve once happened. 

These particles can come from construction moisture or cigarette smoke, 
but  also  they  might  be  volatile  components  in  paint,  construction 
materials  or  carpeting.  For  newly  constructed  chimneys  or  after  a  big 
reconstruction, it is advised to wait a minimum of six weeks before firing 
a fireplace. After this burn-off period, turn off the fireplace and let it cool 

completely to room temperature and once again clean both sides of the 
glass as well as the interior panels.  

11�3�2 

SMELL CHECK

When the fireplace is first heated, an odor may be given off by the hot 
metal. Make sure the device and enclosure are ventilated enough, so the 

possible released fumes are being abducted. The fumes are the result of 

the ‘burn off’ of the lubricants and sealants used when manufacturing 
the fireplace. 

We advice to be as little in the room as possible during this process. It is 
recommended that you open the nearby windows for extra ventilation 

and then operate the fireplace for at least four hours.

11�3�3 

SOUND CHECK

Since  the  product  is  a  metal  fireplace,  the  heat-up  and  cool-down 

cycles may produce some (initial) noises caused by the expansion and 
contraction of these metals. These are normal but should not be audible 

at more than a meter distance from the fireplace. 

Содержание E4-35

Страница 1: ...INSTALLATI O N MA NUAL INSTALLATI O N MA NUAL Please leave these instructions behind with the device K U D O S...

Страница 2: ...INSTALLATION MANUAL i Do not use this product as a primary heat source...

Страница 3: ...G WALLS 7 6 FIRE SAFE INSTALLATION 8 6 1 FIRE SAFETY DEVICE SET UP 8 6 1 1 PROTECTION OF WALL AND CEILING 8 6 2 ASSEMBLY REGULATIONS WITH FLAMMABLE MATERIALS 8 6 2 1 FLOOR PROTECTION 8 6 2 2 RADIATION...

Страница 4: ...ORS CODES PROCONTROL APP 24 B A MESSAGES SHOWN IN APP 24 B B MESSAGES SHOWN IN REMOTE 25 C FAULTS AND ERROR CODES IN THE REMOTE 26 C A F41 ERROR 26 C B ROUTER INFORMATION 26 C B A MINIMUM REQUIREMENT...

Страница 5: ...ke sure it is accessible at all times This device may not be used a primary heat source This device is designed to be used with natural gas or LPG The device can only be used with the type of gas spec...

Страница 6: ...sembly error or material defect Element4 will provide a free replacement part to the installer without compensation for disassembly or montage 5 In case the installer is not able to fix the problem hi...

Страница 7: ...ON 1 2 OFF Figure 3 1 Remote and ignition sign Figure 3 2 Gas Block Figure 3 3 Top and side view of the Receiver 4 2 IGNITING THE PILOT LIGHT Check that the control knob A is in the ON position Figur...

Страница 8: ...e in the near vicinity of the device Position the gas connection such that it is always accessible for service purposes The gas block and receiver are under the combustion chamber in the deivce so tha...

Страница 9: ...contain flammable building materials and all walls on which flammable objects e g built in furniture or wooden panels are mounted on the side of the wall that is turned away from the fireplace Walls c...

Страница 10: ...ombustible materials Top A a a H G Figure 6 1 Distances to combustible materials front B A a a C E D Figure 6 2 Floor plate Letter Minimum Distance to flammable materials mm A 120 B 350 C 300 D 600 E...

Страница 11: ...ach category refers to a set of tables 1 A table for horizontal outlet 2 A table for vertical outlet You must use the table applicable to you You calculate your total vertical section TVS as well as y...

Страница 12: ...L Follow the following instrucions for the installation of flue materials Drill a hole of 160 mm for the wall or roof transit In a situtation of non combustible materials keep a distance of at least 5...

Страница 13: ...vice for a period of one week to ensure yourself of an optimal desired room temperature Also the device can changed between high and low flames and it features an eco setting The amount of users that...

Страница 14: ...e test points on the gas valve can be reached and the relevant button can also be reached for a reset of the receiver 9 3 THE COMBUSTION CHAMBER The glass must be removed to enter the combustion chamb...

Страница 15: ...NSTALLATION MANUAL Figure 9 2 Front view after glass removal Figure 9 3 Gas control in brackets under fireplace Figure 9 4 Hooks on windows 1 2 Figure 9 5 Removal of front frame 1 2 Figure 9 1 Positio...

Страница 16: ...this is the case check the burner pressure at the inlet to the burner The instructions of changing the burner pressure and the correct pressure per gastype can be found in 9 6 2 PILOT The pilot flame...

Страница 17: ...peration of the appliance 10 DECORATIVE CERAMIC PARTS This appliance is equipped with a ceramic fire bed with heat resistant ceramic fibers or artificial glassy silicate fibers Excessive exposure to t...

Страница 18: ...rid and place the indicated logs in the correct place on the grid For the rest of the logs it is important that the grate is not too full If necessary adjust the position of the decoration material if...

Страница 19: ...ble plus button to switch between burners Flames and soot During this first fire examine the flame for appearance and quality Flames may appear blue at first but will turn yellow after 15 to 20 minute...

Страница 20: ...turbs the reception Change the position of the antenna See Figure A B C No ignition no beep 1 Receiver defective Reset the receiver See K1 If necessary replace the receiver D No ignition receiver give...

Страница 21: ...Appendix A INSTALLATION MANUAL Figure A A Bend pin Figure A B Antenna Figure A C Torx screw Figure A D Testpoint 4 5 mV 4 5 mV Figure A E Interrupter Figure A F Wiring receiver 40mm Figure A G Pilot s...

Страница 22: ...ouple Position burner grate 3 Airflow in the burner chamber causes a restless fire image Check drain configuration Fit a flue gas limiter I Receiver gives 3 short beeps after each command 1 Batteries...

Страница 23: ...Aux position receiver AM PM ON 1 2 OFF Figure A L Double plus button on the remote Figure A M SI port PANEL G60 ZCE 1000 MA GR MO SW 2 1 3 MODE Ignition Main Burner High Flames Pilot Extinguish Main...

Страница 24: ...ed Please note If a problem is found that cannot be solved on site always contact your dealer or directly contact Element4 via our credentials which can be found on the back page of this manual 00 00...

Страница 25: ...eeps for 3 sec during motor turn Low Receiver battery power supply F10 Contact Service Pilot lit Main burner fails to ignite and pilot shuts off Ignition is blocked for 2 minutes 2nd thermocouple is o...

Страница 26: ...mmunication between Receiver and myfire Wi Fi Box F44 Contact Service No temperature shown in App N a not applicable displayed in App Handset not within range Low battery power in handset F49 Contact...

Страница 27: ...istances from occurring Many people put the router in the meter cupboard because that is where the internet comes in at many households A bad choice For a powerful WiFi signal the router needs as much...

Страница 28: ...NAL LOCATION WITH VERTICAL EXHAUST C11 Distance Exhaust 1 2 of 3 At the same roof level 6m At a different roof level 3m On a lower wall 2m On a higher sloping surface 6m Distance minimum distance requ...

Страница 29: ...O O V V 6 O O O O O O V V 5 O O O O O O V V 4 O O O O O O V V 3 5 O O O O O O V V 3 V V V V V V V V 2 5 V V V V V V V V 2 V V V V V V V V 1 5 V V V V V V V X 1 V V V V V X X X 0 5 X V V X X X X X 0 1...

Страница 30: ...ner 1x 140 FlatBurner 2x 160 LogBurner 1x 120 FlatBurner Type of flue C11 C31 C91 Additional electricity use At rated heat output elmax 9 5 kW With minimal heat emission elmin 9 5 kW In standby mode e...

Страница 31: ...longs to G A ECOLABELS The ecolabels for the different types of gas are indicated below respectively G20 G25 and G30 From 2022 the UKCA label is used for the United Kingdom Both versions may be found...

Страница 32: ...awings of the fireplace with some of the important dimensions that you have to take into account when installing and installing your fireplace 710 50 704 00 350 00 270 00 80 00 550 00 19 00 588 00 483...

Страница 33: ...Info element4 nl www element4 nl 19 01 22 ELEMENT 4 B V Design Assembly by RELEASE DATE...

Отзывы: