8
SPECIFICATIONS and DIMENSIONS
Element4 Gas Fireplaces
European
Home
.com
APPLIANCE RATINGS
Mode
l
Optica
Bioptica
Gas
Natural Gas
Propane
Input Maximum
Btu/hr
30,730
26,300
Input Minimum
Btu/hr
17,070
8,535
Maximum Supply
Pressure
in. w.c.
7
11
kpa
1.74
2.74
Minimum Supply
Pressure
in. w.c.
4
8
kpa
1
2
Manifold Pressure
Maximum
in. w.c.
2.0
10.6
kpa
0.5
2.64
Manifold Pressure
Minimum
in. w.c.
0.8
1.4
kpa
0.2
0.34
Main Burner Injector Marking
1200
380
Pilot Injector Marking
31.2
27.1
Efficiency
83%
AC Adapter Connection (arrow)
AC ADAPTER SPECIFICATIONS
Input Voltage
120V AC
Input Power
9 W
Output Voltage
6V DC
Output Current
500 mA
Size
3.1”H x 2”W x 1.7”D
Output Cord Length
6 Feet
Agency Approvals
UL, CSA
AC Adapter
A typical rating label is shown above. It is attached to every
Element4 fireplace and contains important certification
information.
It must not be removed from the fireplace.