52
Element4 Gas Fireplaces
European
Home
.com
APPENDIX TWO
Receiver batteries low. Test the batteries, replace if necessary.
Quality 1.5V AA alkaline recommended.
Impulse magnet not
operating properly.
Replace gas valve.
B.
Magnet unit is
energized thus pro-
ducing an obvious
latching sound.
No beep
3 short beeps
1 long beep
8-wire cable is off or
not operating
properly.
Confirm proper operation of the 8-wire
cable.
SW-cable
disconnected.
Confirm proper connection/operation of
the SW-cable.
Motor not operating
properly.
Replace gas valve.
Micro switch not
operating properly.
Replace gas valve.
ON/OFF switch is in
the OFF (O) position.
If equipped, set switch to ON (
|
) position.
2nd thermocouple
not connected
Confirm integrity of 2nd thermocouple and
connection.
No
No
No
Yes
C.
Spark will occur
each second.
Ignition components not
operating properly.
Check connection between ignition cable and ignition
electrode.
Check ignition electrode spark gap.
Check ignition electrode.
Check ignition cable for damage.
Increase distance between ignition cable and all metal
parts.
No
Ignition sequence stops, no pilot flame.
No reaction to
remote
command.
Reset system, see the installation manual or
the label on the receiver.
Do not coil the ignition cable.
Shorten the ignition cable, if possible.
No
Ignition sequence stops, no pilot flame.
Remote
command is possible.
Test the batteries, replace if necessary.
Quality 1.5V AA alkaline recommended.
No
Yes
(continued)
FUNCTION
POSSIBLE CAUSE
REMEDY
Ignition sequence stops after one spark Remove ground bolt (T20 Torx, above) and
clean ground lug.
No