13
EN
Operating and assembly instructions HRD
www.elektror.com
9026998 01.20/13
Also make sure that no hazardous situation can occur as a
consequence of restarting after shutdown, e.g. as a result of
a power cut or blockage.
1.4 Weight and stability
Beware of falling hazards during transportation and installa-
tion in particular. Refer to 2.1 – Transportation and handling,
as well as 3.2 – Installation and assembly.
1.5 Suction e
ff
ect
The blowers produce a powerful suction e
ff
ect.
Warning!
Objects, items of clothing and also hair can be
sucked into the intake port. Risk of injury!
Do not stand near the intake opening during op-
eration. The blower must not under any circum-
stances be operated with the intake port open,
and should, therefore, be covered with a wire
guard in conformity with DIN EN ISO 13857
(danger of injury from impeller!).
1.6 Blowing e
ff
ect
Warning!
The blowing e
ff
ect is very powerful on the ex-
haust side. Sucked in objects may be ejected at
very high speed (danger of injury).
The blowers are designed for delivery of clean
air only. To reliably prevent the sucking-in of
foreign objects or contaminants, which might be
discharged, these objects have to be removed be-
fore entering into the blower by installing a
fi
lter.
Do not reach into the exhaust.
1.7 Temperature
Warning!
The blower housing assumes the temperature
of the conveyed medium during operation. If the
temperature of the conveyed medium is above
+50°C, the blower must be protected against
direct contact by the operator
(risk of burn injury).
In the case of high-power models in particular, the tempera-
ture of the conveyed medium can increase as it
fl
ows from
the intake side to the exhaust side. The temperature di
ff
er-
ence can be in the region of up to +20°C, depending on the
operating conditions. This varies from one model to another.
1.8 Protective grating of the belt drive (if installed -
applies to blowers with motor and belt drive)
Warning!
The belt drive is covered by a protective grating.
Do not put the blower into operation if the protec-
tive grating is not attached and securely bolted in
place (risk of injury!)
1.9 Motor circuit breaker
Before putting the blower into operation, be sure to safe-
guard the drive motor with a motor circuit-breaker (this does
not apply to frequency-converter-operated appliances).
Where appliances are frequency-converter-operated, the ex-
isting temperature sensor (PTC resistor sensor) or tempera-
ture switch (normally closed contact) must be connected to
the converter and evaluated.
1.10 Noise emission
Note!
Wear hearing protection during operation at a
daily exposure level of 80 dB(A) and above, and/
or a peak sound pressure level of 135 dB(C) and
above.
Failure to do so may cause hearing damage.
The noise generated by a blower is not constant throughout
the performance range. For details of noise emission levels,
please refer to the table on pages 20 to 27.
In some cases, sound insulation may be necessary (it is rec-
ommended that emission levels be measured by the opera-
tor). Sound insulation must be provided by the operator to
avoid exceeding the statutory maximum levels at the work-
place and in the immediate vicinity of the blower.
No sound insulation of any kind whatsoever should cause
the ambient temperature to 40°C at the drive motor
(this is not permissible).
1.11 Speeds
Warning!
The maximum speed stamped on the motor rating
plate must never be exceeded in order to prevent
personal injury. The blower is at risk of mechani-
cal damage if the speed is exceeded.
This can cause serious injury or death!
Each component on the blower has unique natural frequen-
cies. These can be induced by certain blower speeds, which
may result in resonance mode.
The blowers are designed in such a way that resonance does
not generally occur at a constant operating speed.
This may be induced in certain circumstances when the
speed is changed if the blower is operated on a frequency
converter. These circumstances are also in
fl
uenced by the
customer’s individual installation situation or ventilation con-
nection.
These natural frequencies must be excluded by parametris-
ing the frequency converter accordingly should they be pre-
sent within the speed range of the blower.
Maximum frequency (see
rating plate)
Minimum frequency
50 Hz
5 Hz
60 Hz
5 Hz
> 60 Hz
20 Hz
Device with temperature
barrier (independent of the
frequency)
35 Hz
1.12 V-belt drive (if installed - applies to blowers with
a motor and belt drive)
Note!
The blowers are equipped as standard with V-belt
pulleys for narrow V-belts according to DIN 7753.
To avoid premature damage to the deep-groove
ball bearings, the V-belt drives must be correctly
pretensioned.
• The blower belt pulley must not be modi
fi
ed.
• The max. permissible blower speed must not be exceeded
Содержание HRD 1/2 T
Страница 11: ...11 www elektror com İşletim ve Montaj Kılavuzu HRD 9026998 01 20 13 TR ...
Страница 21: ...21 DE 9026998 01 20 13 www elektror de Betriebs und Montageanleitung HRD ...
Страница 37: ...37 DE 9026998 01 20 13 www elektror de Betriebs und Montageanleitung HRD ...
Страница 38: ...38 DE Betriebs und Montageanleitung HRD www elektror de 9026998 01 20 13 ...
Страница 39: ...39 DE 9026998 01 20 13 www elektror de Betriebs und Montageanleitung HRD ...