![Elektron 328 008 Скачать руководство пользователя страница 46](http://html1.mh-extra.com/html/elektron/328-008/328-008_operating-manual_2386798046.webp)
Resistance Welder MULTISPOT MI-100-3
Maintenance
46
8.2.4
Empty cooling water tank
Scald hazard
DANGER! Scalding may occur due to hot water coming out!
While pulling out the cooling water hoses hot water may come out. Therefore:
– Wear gloves.
– Pull out water hoses carefully.
Slip hazard
DANGER! Slip hazard due to water coming out!
While pulling out the cooling water hoses water may come out. Therefore:
– Remove water from the floor.
Fig. 52: Filling up the cooling water tank
1.
Remove rear cover, pull out forward and return hose from the cooling water tank.
2.
Cooling water tank carefully pull out, straighten up and turn off cooling water tank cap.
3.
Cooling water tank emptying, observing disposal regulations.
4.
Fill about 30 litres / 7.9 gallons of cold, clean drinking water into the tank.
5.
Add chlorine-free disinfectant to prevent growth of algae and bacteria.
6.
Cooling water tank cap firmly turn up again. Check tightness.
7.
Cooling water tank reinstall. Put forward and return hose into the coolant tank and plug back cover
down and hang up.
8.
Before you switch on the welder, check the coolant level before each use and, if necessary, top up
coolant.