42
X7: Input, pull switch/radio receiver
Connection of a pull switch or external radio receiver via terminals X7/1 and X7/2. The
switching contact must be potential-free (NO contact).
Pull switch or radio receiver function
Menu item "2.6":
Pulse type
Reaction upon activation
"1"
The door CLOSES from the OPEN final limit position or the intermediate
stop position
The door OPENS from all other door positions or door movements
"2"
OPEN-STOP-CLOSE-STOP-OPEN command sequence
"3"
Door always executes OPEN movement