Electrical operating instructions

Door control panel TS 958

Software 1.2 - (Design and functions subject to change)

51171324 

-

 

g 02.2013

en

Содержание TS 958

Страница 1: ...Electrical operating instructions Door control panel TS 958 Software 1 2 Design and functions subject to change 51171324 g 02 2013 en...

Страница 2: ...NNECTION internal wiring 10 RAPID ADJUSTMENT OF THE LIMITS 11 HARDWARE OVERVIEW 12 WIRING DIAGRAM 13 CONTROL PROGRAMMING 14 Operating mode 15 Door position 15 Functions 15 Safety functions 15 Maintena...

Страница 3: ...19 Fully closed control 19 Potential free changeover contact X9 19 Door overload monitor 20 Maintenance cycle counter 21 Short circuit overload monitor 21 OPERATING STATUS DISPLAY 22 TECHNICAL DATA 2...

Страница 4: ...arage doors and gates Safety in use of power operated doors Requirements and left the factory in perfect condition from the point of view of safety To maintain this condition and to ensure safe operat...

Страница 5: ...ate back up fuse must be provided Check live cables and conductors regularly for insulation faults or breakages When a fault is detected in the cabling the defective cabling should be replaced after i...

Страница 6: ...l page 8 Check Mains supply page 9 Check Phase rotation page 10 Programming Rapid limit adjustment page 11 The door is ready to work Installation Spiral cable if required page 13 19 Programming Door f...

Страница 7: ...tton Emergency stop Switch contact potential free Connection cable ELEKTROMAT for Motor and DES electronic limit 11 5 3 3 Spiral cable 2 Number of cores in the cable Important Using the connection cab...

Страница 8: ...trol are fitted they can be connected with a plug in cable The cable has plugs on each end and for easy fitting The plugs for motor and control panel are different and cannot be interchanged Connectio...

Страница 9: ...he right terminal otherwise the print could be destroyed 400V mains supply 1 5 1 6 230V mains supply 1 6 1 7 MAINS SUPPLY External fuse Control must be saved against short circuit and overload by an e...

Страница 10: ...hrough electric shock Before changing phase rotation the mains supply must be switched OFF Three phase 3 x 400 V AC N PE Star connection Three phase 3 x 230 V AC PE Delta connection Single phase 1 x 2...

Страница 11: ...changes 3 Setting the final limit close press button to reach lower limit Display blinking Door close 4 Memorise the final limit close Press stop button for 3 sec until the display changes Display cha...

Страница 12: ...gment display 1 9 L1 fused with F1 1A MOT Motor connection 1 8 N DES Limit connection only with 3 x 400V N PE und 1 x 230V N PE Internal push button X2 Safety edge system and pass door plug X3 Emergen...

Страница 13: ...ation Key switch with stop button Close Stop Open Stop Open Close Key switch intermediate stop Aux contact Bridge passdoor slack wire switch contact spiral cable Open Close or plug in bridge or Emerge...

Страница 14: ...Enter programming Mode Press selector switch for 3 sec until display 00 2 Chose program and confirm Turn selector Press selector 3 Adjustment Turn selector Press foil buttons 4 Memorise Press selector...

Страница 15: ...position Relay switch position Press stop Button Press selector Press selector Press stop Button Move door upwards or downwards Final limit close coarse adjustment Final limit open can change without...

Страница 16: ...es Counter adjustment Display appears CS and adjusted number of cycles Reaction when reaching 0 Maintenance cycle counter 4 Set 3 Adjustment 2 Chose program and confirm Press selector Press selector C...

Страница 17: ...on M HT ZT T H Z E Press selector Press selector M HT ZT T H Z E The cycles would be displayed as follow M 1 000 000 H 100 HT 100 000 Z 10 ZT 10 000 E 1 T 1 000 The Number of program changes would be...

Страница 18: ...PEN command is given after the door controller has detected beforehand asymmetrical pass door switch positions see below for reasons This fault can be reset when the door is reopened This ensures that...

Страница 19: ...cable Push the plugs through into the enclosure until there is sufficient cable to allow the plug to be connected to the board If passdoor slack wire switch contact exists remove bridge at terminal S...

Страница 20: ...force monitoring the door must perfom a complete opening and closing cycle without an interruption Durich which the system reads the increments to calculate the way Important Note The overload monito...

Страница 21: ...nance is agreed The no of cycles can be adjusted from 1 000 up to 99 000 the adjustment is possible in steps of 1 000 cycles Different reactions can be chosen if the point of pre adjusted maintenance...

Страница 22: ...contact open X 2 1 X 2 2 Check the proper operation of pass door contact or whether the supply cable is broken Emergency stop activated Check the emergency stop is activated or whether the supply cabl...

Страница 23: ...tion turning Check phase rotation Phase rotation failure Check main supply phase rotation turns right Check electronic limit DES connection To acknowledge the fault switch OFF ON on the mains or disco...

Страница 24: ...ose command being given Report Command description closing door stopped between set limits Report Status door stopped at upper limit door stopped at lower limit opening flashing flashing adjusted cycl...

Страница 25: ...rnal supply fuse 10A delayed Permitted Load ca 15 VA without motor and ext 230V External supply 230V via L1 and N safety fuse F1 1A t Inputs 24V DC typ 10mA signal length must be more than 100ms Relay...

Страница 26: ...we recommend a replacement for control boards in use after doors having reached their confirmed lifetime cycles Coherence between power and amount of cycles for ELEKTROMATEN describes diagram bellow...

Страница 27: ...ant technical documents internal EU address Dipl Ing Bernd Synowsky Documentation representative Incomplete machines within the meaning of the EC Directive 2006 42 EC shall only be intended to be inte...

Страница 28: ...and close Self hold open and dead man mode close Fully closed control Supply for external devices 230V at 400V 3 with N up to 1A load Plug for 5 pole motor connector 6 pole for electronic limit DES P...